FDA Adverse Event Injury Summary report: N

2008K HEMODIALYSIS MACHINE

MDR report key: 4091631 · Received August 22, 2014

Report

Report Number
2937457-2014-02272
Event Type
Injury
Date Received
August 22, 2014
Date of Event
July 25, 2014
Report Date
July 25, 2014
Manufacturer
FRESENIUS MEDICAL CARE NORTH AMERICA
Product Code
KDI
PMA / PMN Number
K994267
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
BIOMEDICAL ENGINEER

Narratives

Additional Manufacturer Narrative · 1

BASED ON THE INFO PROVIDED, IT IS UNK HOW THE DEVICE MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT. THE POST MARKET CLINICAL DEPARTMENT IS IN THE PROCESS OF REQUESTING PT MEDICAL RECORDS AND TREATMENT DATA INFO REGARDING THE REPORTED HOSPITALIZATION AND DIAGNOSIS OF HEMOLYSIS. ACCORDING TO THE BMT, EXCEPT FOR THE 250 DIALYZER, THERE WERE NO OTHER FRESENIUS PRODUCTS IN USE DURING THE TREATMENT. A SEARCH OF THE DELIVERY HISTORY CONFIRMS THIS. HE REPORTS ALL TESTS FOR CHEMICAL RESIDUAL IN THE LOOP AND DIALYSIS MACHINE WERE NEGATIVE. THERE WERE NO REPORTS OF MACHINE CONDUCTIVITY OR TEMPERATURE PROBLEMS PRIOR TO OR DURING TREATMENT AND THE MACHINE'S PERIODIC MAINTENANCE IS BEING DONE EVERY 6 MONTHS. HE DENIES ANY ELEVATED WATER/DIALYSIS CULTURES. ACCORDING TO THE NURSE MANAGER, THE PT WAS THE ONLY PT IN THE UNIT HOOKED INTO THE CENTRAL DIALYSATE DELIVERY SYSTEM. ALL OTHER PTS WERE RUNNING ON JUG DIALYSATE REPORTEDLY, BECAUSE THE BICARB TO THE CENTRAL SYSTEM WAS "LOW". HE STATES NO CONCLUSIONS HAVE BEEN REACHED RE: THE CAUSE OF THE EVENT. ADDITIONALLY, HE CANNOT RULE OUT "A PRIMING ISSUE OR OTHER ERROR". A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED UPON COMPLETION OF THE INVESTIGATION.

Description of Event or Problem · 1

A BIOMEDICAL TECH (BMT) REPORTED TO TECHNICAL SUPPORT THAT A HEMODIALYSIS PT "EXPERIENCED" HEMOLYSIS DURING A HEMODIALYSIS TREATMENT. ACCORDING TO THE BMT UPON F/U OF THE EVENT, THE MACHINE WAS PULLED FROM SERVICE AFTER THE EVENT AND HE PERFORMED AN INVESTIGATION. THERE WAS NO MALFUNCTION FOUND AND IT PASSED ALL TESTS AND WAS RETURNED TO THE TREATMENT ROOM FLOOR WITHOUT FURTHER INCIDENT. ADD'L F/U WAS DONE WITH THE NURSE MANAGER WHO REPORTED THE PT PRESENTED TO TREATMENT IN HIS USUAL STATE OF HEALTH. HIS ARTERIOVENOUS FISTULA WAS ACCESSED WITHOUT ISSUE AND NO INDICATION OF ANY PROBLEM WAS NOTED WITH THE TREATMENT. APPROX 40 MINUTES INTO THE TREATMENT, THE PT BECAME DIAPHORETIC, COMPLAINED OF A HEADACHE, AND WAS "UNCOMFORTABLE". THE STAFF PERSON RINSED BACK THE PT'S BLOOD AND THE NURSE MANAGER NOTED IT HAD A "BROWN COLOR". HE DENIED BLOOD LOSS. THE PT WAS STILL DIAPHORETIC AND UNCOMFORTABLE AND WAS SENT TO THE EMERGENCY ROOM VIA AMBULANCE. HE WAS ADMITTED TO THE HOSPITAL AND WAS DISCHARGED HOME ONE WEEK LATER. THE NURSE MANAGER DENIES ANY KNOWLEDGE OF TREATMENT RECEIVED WHILE ADMITTED. PT HAS RESUMED HIS THRICE WEEKLY HEMODIALYSIS TREATMENTS WITHOUT FURTHER ISSUE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
508098 2008K HEMODIALYSIS MACHINE KDI FRESENIUS MEDICAL CARE NORTH AMERICA

Patients

Seq Age Sex Outcome Treatment
1 48 YR Hospitalization| R FRESENIUS 250 DIALYZER