GLENOID SCR EPOCA Ø3.5 L24 TAV
Report
- Report Number
- 3000270450-2014-10075
- Event Type
- Injury
- Date Received
- August 7, 2014
- Report Date
- July 8, 2014
- Manufacturer
- SYNTHES SELZACH
- Product Code
- KWT
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
THIS DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. DATE OF EVENT UNKNOWN. AN IMAGE READING OF THE X-RAYS WAS CONDUCTED BY A MEDICAL DIRECTOR FROM THIS MANUFACTURER. THE MEDICAL DIRECTOR SAYS , I CAN CONFIRM HEAD DISLOCATION CAN BE OBSERVED. ADDITIONAL PRO CODES: MBF, HSD. (B)(6). INVESTIGATION COULD NOT BE COMPLETED, NO CONCLUSION COULD BE DRAWN AS NO DEVICE WAS RETURNED. THE REVIEW OF THE DEVICE HISTORY RECORD SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THE PRODUCT THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. THERE WERE NO NCRS GENERATED DURING PRODUCTION. DEVICE IS NOT DISTRIBUTED IN THE UNITED STATES, BUT IS SIMILAR TO DEVICE MARKETED IN THE USA. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
DEVICE REPORT FROM SYNTHES (B)(4) REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT INITIALLY HAD A DEPUY REVERSE SHOULDER IMPLANTED (DELTA CTA) IN 2007. ON (B)(6) 2013, THE PATIENT FRACTURED THE GLENOID AND AS THERE WERE NO DEPUY PRODUCTS THAT WOULD HAVE SUPPORTED THAT FRACTURE. A SYNTHES EPOCA CAGE WAS PUT INTO THE GLENOID, A DELTA STEM AND THE DEPUY HEMI HEAD REMAINED IN SITU TOGETHER. ON (B)(6) 2014, THE PATIENT HAD UNDERGONE A REVISION, AS A RESULT OF THE SYNTHES SCREWS IMPINGING AND CAUSING PAIN. THE SURGEON THOUGHT THE SCREWS WERE TOO LONG. IN ORDER TO GAIN ACCESS TO THE SCREWS, THE DEPUY HEAD WAS ALSO REMOVED AND REPLACED. IT IS UNDETERMINED WHAT CAUSED THE PAIN, SO EVERYTHING WAS TAKEN OUT AND WAS REPLACED WITH DIFFERENT HARDWARE. ON (B)(6) 2014, THE PATIENT HAD THEN UNDERGONE A THIRD REVISION DUE TO HEAD DISLOCATION BY THE SAME SURGEON AND AT THE SAME HOSPITAL. THERE WAS NO TRAUMA INVOLVED THAT COULD HAVE CONTRIBUTED TO THE REPORTED DISLOCATION. AN X- RAY PHOTO IS PROVIDED ON AN UNKNOWN DATE. THE SURGEON DID NOT MAKE COMMENTS TO INDICATE WHETHER THE PATIENT DISLOCATED DUE TO SOFT TISSUE INSUFFICIENCY OR PRODUCT PERFORMANCE. THIS IS REPORT 2 OF 3 FOR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 462833 | GLENOID SCR EPOCA Ø3.5 L24 TAV | PROSTEHESIS, SHOULDER, NONCONSTRAINED, METAL/POLYMER CEMENTED | KWT | SYNTHES SELZACH | 11C18940 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |