Report
- Report Number
- 0001825034-2014-06639
- Event Type
- Injury
- Date Received
- July 31, 2014
- Date of Event
- October 22, 2012
- Report Date
- June 30, 2016
- Manufacturer
- BIOMET ORTHOPEDICS
- Product Code
- KWA
- PMA / PMN Number
- PK042037
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- ATTORNEY
Narratives
CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY OR DEVIATION. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, ¿MATERIAL SENSITIVITY REACTIONS.¿ NUMBER 6 STATES, ¿INADEQUATE RANGE OF MOTION DUE TO IMPROPER SELECTION OR POSITIONING OF COMPONENTS.¿ NUMBER 14 STATES, ¿INTRAOPERATIVE OR POSTOPERATIVE BONE FRACTURE AND/OR POSTOPERATIVE PAIN.¿ NUMBER 15 STATES, ¿ELEVATED METAL ION LEVELS HAVE BEEN REPORTED WITH METAL-ON-METAL ARTICULATING SURFACES.¿ THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 1 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2014-06639 & 06640).
THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH.
THIS FOLLOW-UP REPORT IS BEING FILED TO CORRECT AND RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH. (B)(4). NOT RETURNED BY ATTORNEY.
LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT A LEFT TOTAL HIP ARTHROPLASTY ON (B)(6) 2008. PATIENT'S LEGAL COUNSEL FURTHER REPORTED PATIENT ALLEGATIONS OF PAIN, DAMAGE TO BONE/TISSUE, LACK OF MOBILITY, METAL POISONING, METALLOSIS AND ELEVATED METAL ION LEVELS. SUBSEQUENTLY, PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2012. A REVIEW OF THE INVOICE HISTORY CONFIRMED THE SURGERY DATES AND INDICATES THE MODULAR HEAD, TAPER ADAPTER AND ACETABULAR CUP WERE REMOVED AND REPLACED. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT A LEFT TOTAL HIP ARTHROPLASTY ON (B)(6) 2008. PATIENT'S LEGAL COUNSEL FURTHER REPORTED PATIENT ALLEGATIONS OF PAIN, DAMAGE TO BONE/TISSUE, LACK OF MOBILITY, METAL POISONING, METALLOSIS AND ELEVATED METAL ION LEVELS. SUBSEQUENTLY, PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2012. A REVIEW OF THE INVOICE HISTORY CONFIRMED THE SURGERY DATES AND INDICATES THE MODULAR HEAD, TAPER ADAPTER AND ACETABULAR CUP WERE REMOVED AND REPLACED. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT OPERATIVE (OP) NOTES REPORTS PATIENT WAS REVISED DUE TO METALLOSIS WITH EARLY LOOSENING OF ACETABULUM. REVISION OPERATIVE NOTES REPORT THE PRESENCE OF EPITHELIALIZED SAC OF BURSAL FLUID, VERTICAL CUP, ARTHROFIBROTIC TISSUE, EXTERNAL ROTATOR MASS ON THE FEMUR, THINLY VISCOUS GRAY FLUID, CHARCOAL COLORED TRUNNION, CAVITARY DEFECT, METALLOSIS, METAL STAINING, AND SCLEROTIC ACETABULUM. IN ADDITION, OP NOTES REPORT THE ORIGINAL REAMING FOR THE ACETABULAR COMPONENT HAD NOT COME OUT AND HAD NOT BEEN CARRIED OUT ALL THE WAY TO THE TRUE DEPTH OF THE ACETABULUM AND THAT THE HORSESHOE-SHAPED STEM WAS STILL INTACT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 447699 | M2A-MAGNUM PF CUP 54ODX48ID | PROSTHESIS, HIP | KWA | BIOMET ORTHOPEDICS | N/A | 914730 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 55 YR | Hospitalization| R |