TALENT AAA
Report
- Report Number
- 2953200-2014-01474
- Event Type
- Death
- Date Received
- July 29, 2014
- Date of Event
- January 30, 2015
- Report Date
- February 1, 2015
- Manufacturer
- MEDTRONIC CARDIOVASCULAR SANTA ROSA
- Product Code
- MIH
- PMA / PMN Number
- P070027
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
(B)(4).
ADDITIONAL INFORMATION WAS RECEIVED FOR THIS CASE. THE PATIENT PRESENTED EMERGENTLY WITH A RUPTURED 8 CM IN DIAMETER ANEURYSM. THE PHYSICIAN MADE NO SUCH STATEMENT REGARDING DEVICE OR PROCEDURE RELATIONSHIP. THE PHYSICIAN CONTINUED TO MONITOR THE PATIENT, HOWEVER THE PATIENT¿S CARE WAS WITHDRAWN AND THE PATIENT EXPIRED. THE PHYSICIAN STATED THAT THE PATIENT¿S CONDITION AND BLOOD LOSS CAUSED DEATH. FILM REVIEW WAS COMPLETED. CTA¿S FROM 5 YEARS POST-IMPLANT WERE REVIEWED. FILMS WERE NON-CONTRAST. THE FILMS REVEALED THAT THE ENDURANT CUFF WAS POSITIONED JUST BELOW THE RENALS. THE PROXIMAL STENT GRAFT OD IS 27MM; THE CUFF IS ANGULATED 65DEG A-P RELATIVE TO THE LIMBS. THE PROXIMAL NECK IS SEVERELY CALCIFIED CIRCUMFERENTIALLY. THE TALENT BIFURCATE WAS POSITIONED APPROXIMATELY 2CM BELOW THE CUFF, AND AN UNKNOWN ANEURX CUFF WAS ALSO SEEN IMPLANTED ACROSS THE FLOW DIVIDER INTO THE LEFT LIMB AND APPEARS CLOSED OFF BY THE ENDURANT AORTIC CUFF. THE BIFURCATE IPSI LIMB WAS PLACED DOWN INTO THE RIGHT COMMON ILIAC ARTERY, AND THE CONTRA LIMB INTO THE LEFT COMMON ILIAC ARTERY. THERE IS MINIMAL SEALING LENGTH DISTALLY; BILATERALLY. LACK OF CONTRAST DOES NOT PERMIT ASSESSMENT OF ANY ENDOLEAK OR STENT GRAFT PATENCY. THE MAX DIAMETER AAA IS 10CM, AND THE AAA APPEARS TO HAVE RUPTURED. FROM THE (NON-CONTRAST) FILMS PROVIDED THE CAUSE OF THE ANEURYSM RUPTURE COULD NOT BE DETERMINED. EARLIER FILMS POST-IMPLANT WERE NOT AVAILABLE FOR REVIEW. THE SOURCE AND CAUSE OF THE POSSIBLE ENDOLEAK COULD NOT BE DETERMINED. IT IS POSSIBLE THAT CONTINUED DISEASE PROGRESSION (NECK DILATATION AND ANGULATION), THE CALCIFIED PROXIMAL NECK, AND THE MINIMAL DISTAL LIMB SEAL LENGTH MAY HAVE ALL CONTRIBUTED.
A TALENT STENT GRAFT SYSTEM WAS IMPLANTED IN A PATIENT FOR THE ENDOVASCULAR TREATMENT OF AN 8.5 CM ABDOMINAL AORTIC ANEURYSM. VESSEL MORPHOLOGY WAS REPORTED AS THE AORTIC NECK WAS REVERSE FUNNEL SHAPED AND VARIED IN DIAMETER FROM 22 MM AT THE RENALS DOWN TO 17 MM AT 15 MM BELOW THE RENALS. THE AORTIC NECK HAD MINIMAL ANGULATION, LITTLE THROMBUS, AND MILD CALCIFICATION. THE PATIENT PRESENTED EMERGENTLY WITH THE 8.5 CM ANEURYSM WITH PAIN BUT WITHOUT A RUPTURE. IT WAS REPORTED A RECENT CT REVEALED THAT THE ILIAC LIMB HAS MIGRATED PROXIMAL DUE TO DISEASE PROGRESSION. THE PHYSICIAN WILL MONITOR THE PATIENT. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 441389 | TALENT AAA | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC CARDIOVASCULAR SANTA ROSA | V00252123 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00070 YR | Death| R |