PERLANE L, PERLANE
Report
- Report Number
- 2032896-2014-00600
- Event Type
- Injury
- Date Received
- July 14, 2014
- Date of Event
- January 21, 2014
- Report Date
- June 13, 2014
- Manufacturer
- MEDICIS AESTHETICS, INC.
- Product Code
- LMH
- PMA / PMN Number
- P040024
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UK
- Reporter Occupation
- PHYSICIAN
Narratives
SECOND DEVICE: RESTYLANE L, RESTYLANE LIDOCAINE. INJECTABLE DERMAL FILLER, LOT #12624, IMPLANT DATE: (B)(6) 2014. THIRD DEVICE: EMERVEL TOUCH, OTHER THERAPEUTIC PRODUCTS, LOT# S2121360006. THE MANUFACTURER'S DEVICE ANALYSIS RESULTS: A TREND ANALYSIS SHOWS THAT THERE IS NO INCREASED TREND OF MEDICAL COMPLAINTS REPORTED FOR RESTYLANE LIDOCAINE (LOT NUMBER 12624), RESTYLANE PERLANE LIDOCAINE (LOT NUMBER 12398) OR ERNERVEL TOUCH {LOT NUMBER 82121360006). A BATCH RECORD REVIEW OF RESTYLANE LIDOCAINE (LOT NUMBER 12624), RESTYLANE PERLANE LIDOCAINE (LOT NUMBER 12398) AND EMERVEL TOUCH (LOT NUMBER S2121360006) DID NOT REVEAL ANY DEVIATIONS OR OTHER OBSERVATIONS THAT INDICATE ANY PRODUCT DEFICIENCIES. ALL CHEMICAL AND MICROBIOLOGICAL TEST RESULTS WERE WITHIN THE SPECIFICATION LIMITS. MANUFACTURER COMMENTS: A CAUSAL RELATION BETWEEN THE EVENTS AND THE TREATMENT IS POSSIBLE. HOWEVER, PREVIOUS FILLER TREATMENTS MIGHT BE A CONTRIBUTING FACTOR. THE EVENTS ARE ADDRESSED IN THE LABELING FOR THE RESTYLANE PRODUCTS AND AN INSTRUCTION FOR USE UPDATE IS ON-GOING FOR EMERVEL TOUCH. (B)(4).
THIS IS A VERBATIM REPORT AS RECEIVED BY (B)(4). CASE REFERENCE NUMBERS (B)(4) ARE SPONTANEOUS CASE REPORTS SENT BY A PHYSICIAN WHICH REFERS TO A FEMALE AGED (B)(6) YEARS. THE PATIENT'S PAST MEDICAL HISTORY INCLUDED HYPOTHYROIDISM [HYPOTHYROIDISM] FOR WHICH SHE IS TAKING THYROXINE. THE PATIENT HAS NO HISTORY OF ALLERGIES. THE PATIENT HAS A HISTORY OF PREVIOUS FILLER TREATMENTS (TESOYLA, SCULPTRA, RESTYLANE, RESTYLANE PERLANE) BETWEEN 2002-2013. ON (B)(6) 2013, THE PATIENT WAS INJECTED WITH EMERVEL TOUCH (LOT NUMBER 82121360006) TO THE DERMIS OF CHEEKS, 0.3 M1 LEFT SIDE AND 0.7 ML RIGHT SIDE WITH NEEDLE, RESTYLANE PERLANE LIDOCAINE {LOT NUMBER 12398) SUBDERMAL TO CHEEKS, 1 M1 EACH SIDE WITH CANNULA, AND AZZALURE TO CROWS FEET AND GLABELLAR AREAS. WITHIN 24 HOURS OF TREATMENT THE PATIENT HAD ONSET OF RIGHT-SIDED SWELLING [IMPLANT SITE SWELLING] OF UPPER AND LOWER EYELID. THE SWELLING WAS SEVERE WITHIN 48 HOURS. THE PATIENT ALSO EXPERIENCED SEVERE RIGHT-SIDED ERYTHEMA [IMPLANT SITE ERYTHEMA], SEVERE RIGHT-SIDED TENDERNESS [IMPLANT SITE PAIN] AND PALPABLE FIRM MASS [IMPLANT SITE INDURATION] OF 3X5 EM OF RIGHT ZYGOMA. ON (B)(6) 2014 THE PATIENT WAS INJECTED WITH 1 ML RESTYLANE LIDOCAINE (LOT NUMBER 12624, SUBDERMAL PLACEMENT USING A 27G CANNULA} IN THE LEFT CHEEK. ON (B)(6) 2014, THIRTEEN DAYS POST-INJECTION, THE PATIENT HAD ONSET OF SWELLING [SWELLING] IN THE LEFT CHEEK. THE REPORTING PHYSICIAN DESCRIBES THE EVENT AS "JELLY-LIKE SUBSTANCE ERUPTING THROUGH SKIN" [IMPLANT SITE EFFUSION] AND ASSESSED THE SEVERITY AS MODERATE. THE PATIENT ALSO HAD SWELLING AND ERUPTION OF JELLY-LIKE SUBSTANCE (HA FILLER) OF THE RIGHT CHEEK WHERE RESTYLANE WAS INJECTED IN (B)(6) 2013. THE PATIENT WAS TREATED WITH HYLASE INJECTIONS TO DISSOLVE THE RESTYLANE ON BOTH SIDES OF HER FACE. THE REPORTER ALSO EXTRACTED SOME JELLY-LIKE SUBSTANCE FROM THE SWOLLEN AREA IN HER RIGHT CHEEK. THE PATIENT HAS NOT HAD ANY FURTHER ERUPTIONS, BUT HAS LOST FACIAL VOLUME (WORSE ON THE LEFT SIDE). THE REPORTING PHYSICIAN HAS ASSESSED THE CASE AS SERIOUS DUE TO SCARRING [IMPLANT SITE SCAR] IN AREAS WHERE SKIN ERUPTED AND LOSS OF VOLUME IN THE LEFT CHEEK FOLLOWING TREATMENT WITH HYALASE. THE REPORTER ASSESSED THE OUTCOME FOR THE EVENTS STARTING IN (B)(6) 2013: SWELLING [IMPLANT SITE SWELLING], ERYTHEMA [IMPLANT SITE ERYTHEMA], FIRM MASS [IMPLANT SITE INDURATION] AND TENDERNESS [IMPLANT SITE PAIN] AS RECOVERED I RESOLVED. THE OUTCOME FOR THE EVENTS STARTING IN (B)(6) 2014: SWELLING [IMPLANT SITE SWELLING] AND"JELLY-LIKE SUBSTANCE ERUPTING THROUGH SKIN" [IMPLANT SITE EFFUSION] IS RECOVERED I RESOLVED WITH SEQUELAE (SCARRING[IMPLANT SITE SCAR]). AS CORRECTIVE TREATMENT FOR THE EVENTS STARTING IN (B)(6) 2013 THE PATIENT RECEIVED THE FOLLOWING TREATMENTS: FLUCLOXACILLIN 500 MG FOUR TIMES A DAY, DOXYCYCLINE 100 MG ONCE DAILY FOR ONE WEEK, PREDNISOLONE 30 MG DAILY FOR 5-7 DAYS THEN REDUCING DOSE AND CETRIZINE 10 MG ONCE DAILY UNTIL (B)(6) 2014. THE EVENTS INITIALLY IMPROVED BUT THE SWELLING INCREASED AGAIN AFTER A FEW DAYS SO PREDNISOLONE WAS INCREASED TO 30 MG AGAIN. AS CORRECTIVE TREATMENT FOR THE EVENTS STARTING IN (B)(6) 2014 THE PATIENT RECEIVED PREDNISOLONE 30 MG 00, DOXYCYCLINE 100 MG 00, AND ANTIHISTAMINES. THE PATIENT WAS ALSO TREATED WITH HYLASE INJECTIONS TO DISSOLVE THE RESTYLANE ON BOTH SIDES OF HER FACE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 409699 | PERLANE L, PERLANE | INJECTABLE DERMAL FILLER | LMH | MEDICIS AESTHETICS, INC. | 12398 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 69 YR | Other | SEVERE RIGHT-SIDED ERYTHEMA,| (IMPLANT SITE SWELLING ((B)(4)))| (IMPLANT SITE PAIN ((B)(4)))| (IMPLANT SITE INDURATION ((B)(4)))| JELLY-LIKE SUBSTANCE ERUPTING THROUGH SKIN,| (IMPLANT SITE SCAR ((B)(4)})| SEVERE RIGHT-SIDED TENDERNESS,| (IMPLANT SITE EXTRAVASATION ((B)(4)))| PALPABLE FIRM MASS,| RIGHT-SIDED SWELLING/SWELLING IN THE LEFT CHEEK,| SCARRING IN AREAS WHERE SKIN ERUPTED,| (IMPLANT SITE ERYTHEMA ((B)(4))) |