FDA Adverse Event Injury Summary report: N

TAPERLOC POR LAT FMRL 15X150

MDR report key: 3953978 · Received July 23, 2014

Report

Report Number
0001825034-2014-06415
Event Type
Injury
Date Received
July 23, 2014
Date of Event
March 6, 2014
Report Date
November 24, 2014
Manufacturer
BIOMET ORTHOPEDICS
Product Code
LPH
PMA / PMN Number
PK030055
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MO, US
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH. THIS REPORT IS NUMBER 5 OF 8 MDRS FILED FOR THE SAME PATIENT (REFERENCE 1825034-2014-04336 / 04339, 06415 / 06416 AND 08889 / 08890).

Additional Manufacturer Narrative · 1

CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY RELATED TO THE EVENT. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS: "DISLOCATION AND SUBLUXATION DUE TO INADEQUATE FIXATION AND IMPROPER POSITIONING. MUSCLE AND FIBROUS TISSUE LAXITY MAY ALSO CONTRIBUTE TO THESE CONDITIONS. " AND "LOOSENING OR MIGRATION OF IMPLANTS MAY OCCUR DUE TO LOSS OF FIXATION, TRAUMA, MALALIGNMENT, BONE RESORPTION, OR EXCESSIVE ACTIVITY. " THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 5 OF 6 MDRS FILED FOR THE SAME PATIENT (REFERENCE 1825034-2014-04336 /-04337 /-04338 /-04339 /-06415 /-06416).

Description of Event or Problem · 1

LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT BILATERAL TOTAL HIP ARTHROPLASTY ON (B)(6), 2008 AND A RIGHT HIP REVISION PROCEDURE ON (B)(6) 2014 DUE TO PATIENT ALLEGATIONS OF PAIN, ELEVATED METAL ION LEVELS, PSEUDOTUMORS, FLUID, AND SOFT TISSUE NECROSIS. THERE HAS BEEN NO REPORTED LEFT HIP REVISION TO DATE. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. OPERATIVE REPORT RECEIVED NOTED PATIENT UNDERWENT A RIGHT HIP REVISION ON (B)(6) 2014 DUE TO PAIN, ELEVATED METAL ION LEVELS, A PSEUDOTUMOR AND SUBLUXATION. OPERATIVE REPORT NOTED THE PRESENCE OF A PSEUDOTUMOR, MURKY BROWNISH YELLOW CLOUDY FLUID, NECROSIS, METAL DEBRIS, IMPINGEMENT ON THE FEMORAL NECK AND CUP, NOTCHED FEMORAL NECK, CUP OVER ANTEVERTED, SYNOVITIS, SOFT TISSUE REACTION, TAPER ADAPTER COLD-WELDED ONTO THE STEM, AND METAL STAINING. ALL COMPONENTS WERE REMOVED AND REPLACED WITH COMPETITOR¿S COMPONENTS.

Description of Event or Problem · 1

LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT BILATERAL TOTAL HIP ARTHROPLASTY ON (B)(6) 2008 AND A RIGHT HIP REVISION PROCEDURE ON (B)(6) 2014 DUE TO PATIENT ALLEGATIONS OF PAIN, ELEVATED METAL ION LEVELS, PSEUDOTUMORS, FLUID, AND SOFT TISSUE NECROSIS. THERE HAS BEEN NO REPORTED LEFT HIP REVISION TO DATE. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. OPERATIVE REPORT RECEIVED NOTED PATIENT UNDERWENT A RIGHT HIP REVISION ON (B)(6) 2014 DUE TO PAIN, ELEVATED METAL ION LEVELS, A PSEUDOTUMOR AND SUBLUXATION. OPERATIVE REPORT NOTED THE PRESENCE OF A PSEUDOTUMOR, MURKY BROWNISH YELLOW CLOUDY FLUID, NECROSIS, METAL DEBRIS, IMPINGEMENT ON THE FEMORAL NECK AND CUP, NOTCHED FEMORAL NECK, CUP OVER ANTEVERTED, SYNOVITIS, SOFT TISSUE REACTION, TAPER ADAPTER COLD-WELDED ONTO THE STEM, AND METAL STAINING. ALL COMPONENTS WERE REMOVED AND REPLACED WITH COMPETITOR'S COMPONENTS. ADDITIONAL INFORMATION RECEIVED IN PATIENT MEDICAL RECORDS REVEALED A LEFT HIP REVISION ON (B)(6) 2014 DUE TO PAIN, METAL-ON-METAL SOFT TISSUE REACTION, AND ELEVATED METAL ION LEVELS. THE PATIENT'S OPERATIVE REPORT NOTED BROWNISH YELLOW FLUID, HEAD/ADAPTER WAS COLD WELDED ONTO THE STEM, A CRACK IN THE GREATER TROCHANTER, AND SPLINTERING AND FRAGMENTATION OF BONE. ALL COMPONENTS WERE REMOVED AND REPLACED WITH COMPETITOR'S COMPONENTS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
431523 TAPERLOC POR LAT FMRL 15X150 PROSTHESIS, HIP LPH BIOMET ORTHOPEDICS N/A 604660

Patients

Seq Age Sex Outcome Treatment
1 62 YR Hospitalization| R