FDA Adverse Event Injury Summary report: N

24K NEURO PROBE SHORT

MDR report key: 3953452 · Received July 10, 2014

Report

Report Number
8010219-2014-00033
Event Type
Injury
Date Received
July 10, 2014
Date of Event
June 17, 2014
Report Date
June 17, 2014
Manufacturer
INTEGRA NEUROSCIENCES, LTD.
Product Code
LFL
PMA / PMN Number
K081459
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
WI, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

TO DATE, THE DEVICE INVOLVED IN THE REPORTED INCIDENT HAS NOT BEEN RECEIVED FOR EVALUATION. AN INVESTIGATION HAS BEEN INITIATED BASED UPON THE REPORTED INFO.

Description of Event or Problem · 1

THIS IS THE SECOND OF FOUR REPORTS (SAME PT, SAME INCIDENT, DIFFERENT PRODUCT IDS/SERIAL NUMBERS). THIS REPORT IS IN REGARD TO THE 24K NEURO PROBE SHORT WITH SERIAL NUMBER (B)(4). LINKED TO MFG REPORT NUMBER: 8010219-2014-00032 (1517079 SELECTOR STERILE TUBING KIT; MFG REPORT NUMBER 8010219-2014-00034 (1523000M7P; 24K NEURO PROBE SHORT SERIAL NUMBER (B)(4)) AND MFR REPORT NUMBER 3006697299-2014-00066 (CUSANXT; CUSA NXT CONSOLE (115-230V) SERIAL NUMBER (B)(4)). IT WAS REPORTED THAT THE 24 NEURO HANDPIECES WERE LEAKING OUT OF THE BACK OF THE HANDPIECES. THE HANDPIECE WAS SWITCHED OUT TO A SECOND LOANER HANDPIECE BUT IT DID THE SAME THING. THE SALES REPRESENTATIVE HAD THE IRRIGATION UP TO 20 AND SHE DID LOWER IT TO 14. THE PT GOT A THERMAL BURN ON THE LATERAL WALL OF THE INNER EYELID. THE SURGEON SAID THE HANDPIECE WAS TOO HOT AND BURNED THE PT. THE SURGEON WOULD HAVE TO REPAIR THE BURN BEFORE CLOSING. THERE WAS A SURGICAL DELAY OF 1 HOUR. ADDITIONAL INFO WAS RECEIVED FROM THE SALES REPRESENTATIVE ON (B)(6) 2014 WITH THE FOLLOWING: DURING AN ORBITAL DECOMPRESSION CASE, THE LENGTH OF TIME THE PRODUCT WAS IN USE BEFORE THE LEAK WAS OBSERVED WAS 10 SECONDS FOR THE FIRST HANDPIECE THEN THE HANDPIECE WAS SWITCHED TO THE SECOND HANDPIECE AND THE LEAK WAS ALSO IMMEDIATE. THE SURGEON USED 2 MINUTES 12 SECONDS FOR ULTRASONIC TIME. THE IRRIGATION WAS LOWERED FROM 20 TO 14 WHEN THE SECOND HANDPIECE WAS BEING USED, MAYBE AFTER 15 SECONDS. IT WAS LOWERED BECAUSE THERE WAS TOO MUCH IRRIGATION GOING DOWN THE SURGEON'S ARM. THE SURGEON ALSO SAID HE HAD PLENTY OF IRRIGATION IN THE STERILE FIELD. THE SALES REPRESENTATIVE HAD THE IRRIGATION SETTING MAINLY AT 20 THE WHOLE 2:12 TIME. IT WAS LOWERED TO 14 WHEN IT DIDN'T HELP WITH THE DRIPPING. THE SALES REPRESENTATIVE RAISED IT BACK UP TO 20. THE SALES REPRESENTATIVE DID NOT KNOW WHICH HANDPIECE WAS THE FIRST OR SECOND HANDPIECE THAT WAS USED AS THEY WERE BOTH IN THE SAME STERILIZATION TRAY. THE SALES REPRESENTATIVE DID NOT KNOW WHICH HANDPIECE GOT TOO HOT AND BURNED THE PT. THE HANDPIECE; TUBING WAS STILL LEAKING WHEN THE BURNED OCCURRED. THE SELECTOR TUBING WAS NOT CHANGED AT ALL DURING THE CASE. THE 1 HOUR SURGICAL DELAY WAS DUE TO CHANGING THE HANDPIECES OUT AND ALSO AT THE END OF THE CASE, THE SURGEON HAD TO DO A REVISION TO THE PT'S EYELID. SURGERY WAS COMPLETED USING THE "DRILL WITH SUCKERS AND IRRIGATION". THIS WAS REPORTED TO BE THE SURGEON'S NORMAL TECHNIQUE. ADDITIONAL INFO WAS RECEIVED FROM THE SURGEON ON (B)(6) 2014 WITH THE FOLLOWING: PATIENT AGE WAS UNAVAILABLE AT THE TIME OF THE REPORT. THE THERMAL INJURY OCCURRED EARLY IN THE LATERAL DECOMPRESSION. THE SURGEON STATED THE HANDPIECE WAS ENERGIZED FOR ONLY 2 MINUTES 19 SECONDS WHEN THE PROBLEM WAS IDENTIFIED AND THE USE OF THE SELECTOR WAS DISCONTINUED. THE WATER LEAK SEEMED QUITE MINIMAL AND SUFFICIENT WATER WAS COMING OUT THE TIP IRRIGATOR NECESSITATING THE USE OF AN ADDITIONAL SUCTION TO CLEAR AWAY THE IRRIGATION FROM THE FIELD. THE BURN OCCURRED ON THE SUPERIOR EDGE OF THE LATERAL CANTHAL SKIN INCISION, RIGHT EYE. THE AREAS OF THERMAL INJURY MEASURED 5 MM X 3 MM AND 4 MM X 2 MM. AT THE END OF THE CASE, THE AREA MOST SIGNIFICANTLY AFFECTED WAS EXCISED (10 MM X 4 MM) AND THE WOUND WAS CLOSED IN A TYPICAL FASHION. THE PT IS STILL HEALING BUT APPEARS TO BE DOING WELL. IT IS NOT KNOW IF ADDITIONAL INTERVENTION FOR THE THERMAL INJURY WILL BE REQUIRED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
403934 24K NEURO PROBE SHORT NA LFL INTEGRA NEUROSCIENCES, LTD.

Patients

Seq Age Sex Outcome Treatment
1 44 YR Other| R SELECTOR STERILE TUBING KIT (PRODUCT ID 1517079,| 24K NEURO PROBE SHORT (PRODUCT ID: 1523000M7P,| LOT NUMBER 1134133| SERIAL NUMBER (B)(4))| CUSA NXT