AQUAMANTYS BIPOLAR SEALER
Report
- Report Number
- 1226420-2014-00052
- Event Type
- Injury
- Date Received
- July 18, 2014
- Date of Event
- May 14, 2014
- Report Date
- June 20, 2014
- Manufacturer
- MEDTRONIC ADVANCED ENERGY, LLC
- Product Code
- DWG
- PMA / PMN Number
- UNK
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MD, US
- Reporter Occupation
- PHYSICIAN
Narratives
PRODUCT EVENT (B)(4). EVALUATION, METHOD, RESULT, CONCLUSION: DEVICES ASSOCIATED WITH ADVERSE EVENTS NOT RETURNED FOR ANALYSIS; THEREFORE, ANALYSIS UNABLE TO BE PERFORMED. (B)(4).
AVERAGE AGE OF PATIENTS INVOLVED IN STUDY: 64.72 YEARS MAJORITY GENDER OF PATIENTS INVOLVED IN STUDY: FEMALE AVERAGE WEIGHT OF PATIENTS INVOLVED IN STUDY: UNDISCLOSED TITLE OF ARTICLE: USE OF A BIPOLAR SEALER IN TOTAL HIP ARTHROPLASTY: MEDICAL RESOURCE USE AND COSTS USING A HOSPITAL ADMINISTRATIVE DATABASE (DOI://10.3928/01477447-20140430-59) RETROSPECTIVE, COMPARATIVE COHORT STUDY IN THE US HOSPITAL SETTING TO ASSESS MEDICAL RESOURCE USE AND ASSOCIATED COSTS AND THE INCIDENCE OF TRANSFUSION AND COMPLICATIONS AMONG PATIENTS UNDERGOING THA WITH OR WITHOUT THE USE OF A BIPOLAR SEALER. THA PROCEDURES FROM JANUARY 1, 2008 - MARCH 31, 2011 (MEAN AGE 65 YEARS FROM 38 HOSPITALS) BIPOLAR COHORT: 2,683 NON-BIPOLAR COHORT: 2,683 RESULTS: SIMILAR INSTANCES OF PRE-OPERATIVE ANEMIA AND MEDICAL CO-MORBIDITIES. PATIENTS IN BIPOLAR SEALER GROUP HAD SIGNIFICANTLY FEWER BLOOD TRANSFUSIONS (21.3% VS. 23.8% P=.0286) SIGNIFICANTLY LOWER INCIDENCE OF HEMATOMAS (.2% VS. .9% P=.0015) SIGNIFICANTLY SHORTER LOS (2.90 VS. 3.31 DAYS P<(><<)>.0001) NO SIGNIFICANT DIFFERENCE IN FREQUENCY AND DURATION OF ICU STAYS (2.0% VS. 1.9% P=.20) TOTAL MEAN HOSPITAL COSTS WERE SIMILAR BETWEEN THE TWO COHORTS ($18,937 VS. $18,734 P=.56) DISCHARGE STATUS DIFFERED SIGNIFICANTLY (P<(><<)>.0001); MORE PATIENTS IN BIPOLAR SEALER GROUP WERE RELEASED TO HOME OR SELF-CARE (33.6% VS. 24.1%), FEWER TO HOME HEALTH ORGANIZATIONS (37.2% VS. 41.4%), OR SKILLED NURSING FACILITIES (23.6% VS. 26.8%) ADVERSE EVENTS REASONABLY RELATED TO USE OF BIPOLAR SEALER: BLOOD TRANSFUSIONS (571 INSTANCES) TRANSFUSION RELATED COMPLICATIONS (2 INSTANCES) POSTOPERATIVE INFECTIONS (97 INSTANCES) SUBSEQUENT NON-ELECTIVE HOSPITALIZATIONS (9 INSTANCES).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 421937 | AQUAMANTYS BIPOLAR SEALER | ELECTROSURGICAL DEVICE | DWG | MEDTRONIC ADVANCED ENERGY, LLC | MAE UNK AQM DEV | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00065 YR |