FDA Adverse Event Malfunction Summary report: N

BLS-100 LED LIGHT SOURCE / BLS-1000 PORTABLE

MDR report key: 3928198 · Received June 20, 2014

Report

Report Number
2242464-2014-00001
Event Type
Malfunction
Date Received
June 20, 2014
Date of Event
May 21, 2014
Report Date
June 20, 2014
Manufacturer
VISION-SCIENCES, INC.
Product Code
EOB
PMA / PMN Number
K050972
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

ALTHOUGH NO ADVERSE HEALTH CONSEQUENCES HAVE BEEN REPORTED FOR ANY OF THE COMPLAINTS, USER (NURSE) RECEIVED A MINOR THERMAL BURN, DESPITE THE EXTREME LOW OCCURRENCE RATE FOR THIS EVENT ((B)(4)). INITIAL INVESTIGATION SUGGESTS INCOMPATIBILITY BETWEEN THE CHARGER AND BATTERY; HOWEVER, TESTING IS STILL BEING PERFORMED TO CONFIRM INITIAL CONCLUSION. NON-CONFORMING REPORT ISSUED TO CHARGERS TO QUARANTINE ALL CHARGES IN STOCK. HOLD-SHIPMENT STATUS HAS BEEN PLACED ON CHARGERS. EXPECTED DATE FOR COMPLETION OF ADDITIONAL TESTING (FAILURE MODE) JULY 15TH, 2014. INITIAL ROOT CAUSE INVESTIGATION PERFORMED ON 06/06/2014 INDICATED THE FOLLOWING: DEVICE - ACCESSORY: BLS-1000: THE REMAINS OF THE BLS-1000, BATTERIES AND CHARGER WERE EXAMINED BY ENGINEERING ON 06/02/2014. REMAINS OF BLS-1000 (BODY) WERE STILL OPERATIONAL. CLOSE EXAMINATION OF THE REMAINS OF THE BLS-1000 BODY SHOW SHRED METAL SEVERELY FRACTURED INDICATING INTENSE PRESSURE BUILD-UP INSIDE THE BLS-1000 BODY RESULTING IN THE RUPTURE OF THE BATTERY COMPARTMENT WITH EXPULSION OF THE BATTERY AND THE CONTENTS. ACCESSORIES: BATTERY CHARGER AND LITHIUM-ION RECHARGEABLE BATTERIES: BATTERY CHARGER WAS EXAMINED AND WAS FOUND TO BE OPERATING NORMALLY. CONCLUSION: THE BATTERY WAS OVER-CHARGED BY THE VANSON V-95 CHARGER. CHARGER HAS BEEN FOUND NOT ADEQUATE TO HANDLE THE CHARGE FOR THIS BATTERY (EEMB LIR 17335). BATTERY SPECIFICATION CALLS FOR CHARGE UPPER LIMIT VOLTAGE OF 4.2 V AND THE VANSON CHARGER UPPER LIMIT VOLTAGE IS 4.45. INTERNAL (B)(4) ASSIGNED TO THE CASE (CURRENTLY IN INVESTIGATION STAGE). ADDITIONAL TESTING IS BEING PERFORMED TO DETERMINE REMEDIAL ACTION. EXPECTED DATE FOR COMPLETION OF ADDITIONAL TESTING (FAILURE MODE) JULY 15TH 2014.

Description of Event or Problem · 1

ON (B)(6) 2014, VISION-SCIENCES INC RECEIVED A REPORT, FROM DISTRIBUTOR IN (B)(6), THAT ONE LIGHT SOURCE BLS-1000 (P/N 07-3050) HAS EXPLODED WHEN SWITCHED ON. THERE WAS NO PATIENT INVOLVED BUT THE NURSE PREPARING THE UNIT WAS SLIGHTLY BURNT AT HAND AND EYE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
363113 BLS-100 LED LIGHT SOURCE / BLS-1000 PORTABLE BLS-1000 LED LIGHT SOURCE SET EOB VISION-SCIENCES, INC. NA

Patients

Seq Age Sex Outcome Treatment
1 NA