COSYCOT INFANT WARMER
Report
- Report Number
- 9611451-2014-00599
- Event Type
- Malfunction
- Date Received
- July 3, 2014
- Report Date
- June 5, 2014
- Manufacturer
- FISHER & PAYKEL HEALTHCARE LTD
- Product Code
- FMT
- PMA / PMN Number
- K971695
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- OTHER
Narratives
(B)(4). METHOD: THE COMPLAINT IW933 WARMER HEAD ASSEMBLY WAS SERVICED BY A CONTRACTOR IN (B)(4). PHOTOGRAPHS OF THE COMPLAINT HEATER HEAD WERE REQUESTED BUT WERE NOT PROVIDED TO US.OUR INVESTIGATION IS THEREFORE BASED ON OUR KNOWLEDGE OF THE PRODUCT. RESULTS: WE WERE INFORMED THAT THE UPPER HEAD CASE OF THE INFANT WARMER WAS CRACKED, BUT NO FURTHER DETAILS WERE PROVIDED. CONCLUSION: IT IS LIKELY THAT THE CRACKING AND CRAZING OF THE COMPLAINT WARMER HEAD IS RELATED TO A KNOWN PROBLEM OF INCOMPATIBLE CLEANING SOLUTIONS REACTING WITH THE POLYCARBONATE PLASTIC AND ACRYLIC COMPONENTS OF THE INFANT WARMER. WHEN THE HEATER HEAD BEGINS TO WARM UP DURING USE A CHEMICAL REACTION WITH THE INCOMPATIBLE CLEANING SOLUTION RESULTS IN GRADUAL CRACKING AND CRAZING OF THE HEATER HEAD. IT MUST BE NOTED THAT THE COMPLAINT UNIT IS OVER 10 YEARS OLD AND THUS THE CRACKING COULD ALSO BE THE RESULT OF IMPACT DAMAGE AND WEAR AND TEAR WHILE MOVING THE WARMER BETWEEN WARDS. THE INFANT WARMER SERVICE MANUAL FOR THE AFFECTED UNIT FEATURES A DIAGRAM OF THE INFANT WARMER WHICH HIGHLIGHTS POLYCARBONATE AND ACRYLIC COMPONENTS AND STATES THE FOLLOWING: CAUTION DO NOT CLEAN THE HIGHLIGHTED PLASTIC SURFACES WITH PROPRIETARY CLEANING PRODUCTS CONTAINING EITHER HYDROXIDES, HYPOCHLORITES, PEROXIDES, GLUTARALDEHYDE OR CLEANING PRODUCTS WITH A GREATER THAN 30% ALCOHOL BASE; CAUTION THE CHEMICALS USED IN THESE PROPRIETARY CLEANING PRODUCTS MAY LEAD TO DISCOLOURATION, CRAZING AND EVENTUAL CRACKING OF THE HIGHLIGHTED PLASTIC SURFACES. AS PART OF OUR CONTINUOUS IMPROVEMENT INITIATIVES ON (B)(4) 2010 WE CHANGED THE MATERIAL USED IN THE MANUFACTURE OF THE HEAD HOUSING TO ONE THAT OFFERS GREATER RESISTANCE TO ENVIRONMENTAL STRESS CRACKING. WE ALSO REVISED OUR CLEANING INSTRUCTIONS TO RECOMMEND SPECIFIC PROPRIETARY CLEANING WIPES. THE COMPLAINT INFANT WARMER WAS REPAIRED AND RETURNED TO THE CUSTOMER FOLLOWING AN ELECTRICAL SAFETY AND PERFORMANCE CHECK.
A SERVICING CONTRACTOR REPORTED THAT WHILE SERVICING AN IW933 COSYCOT INFANT WARMER FROM A HOSPITAL IN (B)(6) THEY FOUND THAT THE UPPER HEATER HEAD CASE WAS CRACKED. THIS WAS FOUND DURING SERVICING AND NOT WHILE IN PATIENT USE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 391437 | COSYCOT INFANT WARMER | FMT | FMT | FISHER & PAYKEL HEALTHCARE LTD | IW933 | 040622 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |