STARDRIVE SCREWDRIVER SHAFT T8 55MM
Report
- Report Number
- 3003875359-2014-10193
- Event Type
- Malfunction
- Date Received
- July 2, 2014
- Report Date
- June 6, 2014
- Manufacturer
- SYNTHES HAGENDORF
- Product Code
- HXX
- PMA / PMN Number
- PEXEMPT
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
Narratives
EVENT DATE: UNKNOWN. DEVICE IS AN INSTRUMENT AND IS NOT IMPLANTED/EXPLANTED. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. NO NON-CONFORMANCE REPORTS WERE GENERATED DURING PRODUCTION. REVIEW OF THE DEVICE HISTORY RECORD SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THE PRODUCT THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. ADDITIONAL NARRATIVE: THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS THE PRODUCT IS ENTERING THE COMPLAINT SYSTEM. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
A PRODUCT DEVELOPMENT EVALUATION WAS COMPLETED: THE 314.453, LOT 3645029 T8 STARDRIVER SHAFT WAS RECEIVED INTACT WITH VISIBLE SIGNS OF WEAR AT THE STARDRIVE TIP AND PROXIMAL ENGAGEMENT TAB. THE DEVICE IS INTENDED FOR USE IN THE ENGAGEMENT AND LOOSENING OF T8 SCREWS THE VARIABLE ANGLE-LOCKING COMPRESSION PLATE SYSTEMS FOR THE ELBOW, DISTAL RADIUS, ANKLE, AND CLAVICLE TO INSERT THE LOCKING SCREWS AND BUTTRESS PINS AS PROVIDED IN TECHNIQUE GUIDES. THE RELEVANT PRODUCT DRAWING AND ENGINEERING STANDARDS WERE REVIEWED DURING THE INVESTIGATION. THE STARDRIVE SCREWDRIVER SHAFT IS A HEXALOBULAR DRIVE FEATURE DESIGNED TO HAVE A SELF-RETAINING EFFECT. THE SCREWDRIVER SHAFT IS MADE FROM HARDENED AND TEMPERED 1.4028 SS AND IS ADEQUATE FOR THE INSTRUMENT¿S INTENDED USE. THE HARDENING AND TEMPERING PROCESS INCREASES THE MATERIALS TOUGHNESS ALLOWING THE INSTRUMENT TO PLASTICALLY DEFORM BEFORE FRACTURING AND THEREFORE REDUCING THE RISK THE INSTRUMENT WILL BREAK. BASED ON THE ENGINEERING STANDARDS FOR THE T8 STARDRIVE SCREWDRIVER BLADE AND THE ENGINEERING STANDARDS FOR THE T8 STARDRIVE RECESS IN SCREWS, THE SCREWDRIVER IS DIMENSIONED AND TOLERANCED APPROPRIATELY ALLOWING ONLY FOR PURPOSELY DESIGNED INTERFERENCE WHICH GIVES THE SCREWDRIVER ITS RETAINING FEATURES. THE MATERIAL AND DIMENSIONS ARE ADEQUATE FOR THE INTENDED DESIGN, APPLICATION AND DIMENSIONAL CONFORMITY WHEN USED AS RECOMMENDED. THE COMPLAINT CONDITION MAY HAVE OCCURRED DUE TO INCORRECT ALIGNMENT AND OVER-TORQUEING OR POWERED DRIVING CAUSING THE STARDRIVE TIP TO BEND. THIS WOULD CREATE INTERFERENCE BETWEEN THE INNER RADIUS OF THE SCREWDRIVER AND THE INNER RADIUS OF THE RECESS ON THE SCREW AS THE CONDITION OF THE STARDRIVE TIP SUGGESTS. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
IT WAS REPORTED SEVERAL INSTRUMENTS WERE FOUND DAMAGED DURING CLEANING AND STERILE PROCESSING. THREE STARDRIVE SCREWDRIVERS, HAVE ALL BECOME WORN AND NO LONGER ARE CAPABLE OF PICKING UP SCREWS. ONE MESH PLATE CUTTER IS BROKEN INTO TWO PARTS AT ONE OF THE END PIECES. ONE HEXAGONAL SCREWDRIVER IS BROKEN AND MISSING THE TIP. THERE WAS NO PATIENT OR PROCEDURE INVOLVED. THIS IS REPORT 1 OF 5 FOR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 385720 | STARDRIVE SCREWDRIVER SHAFT T8 55MM | SCREWDRIVERS | HXX | SYNTHES HAGENDORF | 3645029 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |