FDA Adverse Event Injury Summary report: N

CARPENTIER-EDWARDS PERIMOUNT® RSR PERICARDIAL BIOPROSTHESIS

MDR report key: 3885020 · Received June 19, 2014

Report

Report Number
2015691-2014-01415
Event Type
Injury
Date Received
June 19, 2014
Date of Event
May 16, 2014
Report Date
May 23, 2014
Manufacturer
EDWARDS LIFESCIENCES
Product Code
DYE
PMA / PMN Number
P860057/S001
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NE, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE DEVICE WAS NOT RETURNED TO EDWARDS FOR ANALYSIS. DEVICE HISTORY RECORD (DHR) REVIEW WAS COMPLETED AND THIS DEVICE PASSED ALL MANUFACTURING AND STERILIZATION INSPECTIONS. WITHOUT THE RETURN OF THE DEVICE, EDWARDS IS UNABLE TO CONFIRM THE CLINICAL OBSERVATION. CALCIFIC DEGENERATION IS A COMMON CAUSE OF BIOPROSTHETIC HEART VALVE FAILURES. MANY FACTORS CONTRIBUTE TO THE ONSET AND PROPAGATION OF CALCIFICATION. THESE INCLUDE PATIENT FACTORS (AGE, DISEASE STATE, PHARMACOLOGICAL INTERVENTION, ETC.), AND MECHANICAL STRESS RELATED TO THE VALVE'S HEMODYNAMIC PERFORMANCE. THOUGH NUMEROUS STUDIES HAVE BEEN CONDUCTED ON PREVENTATIVE CALCIFICATION STRATEGIES IN BIOPROSTHETIC HEART VALVES, THE CAUSES OF CALCIFICATION ARE NOT FULLY UNDERSTOOD AND THERE ARE STILL NO MECHANISMS OR MEDICAL THERAPIES WHICH FULLY PREVENT BIOPROSTHESES FROM CALCIFYING. EDWARDS WILL CONTINUE TO REVIEW AND MONITOR ALL EVENTS. TRENDS ARE MONITORED ON A MONTHLY BASIS AND IF ACTION IS REQUIRED, APPROPRIATE INVESTIGATION WILL BE PERFORMED.

Description of Event or Problem · 1

EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, THE PERICARDIAL VALVE, IMPLANTED THIRTEEN (13) YEARS, REQUIRED VALVE IN VALVE INTERVENTION. FURTHER INVESTIGATION REVEALED BIOPROSTHETIC VALVE EXHIBITED SEVERE AORTIC REGURGITATION AND CALCIFICATION. IT WAS REPORTED PATIENT TOLERATED THE PROCEDURE WELL.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
361936 CARPENTIER-EDWARDS PERIMOUNT® RSR PERICARDIAL BIOPROSTHESIS REPLACEMENT HEART VALVE DYE EDWARDS LIFESCIENCES 280023MM

Patients

Seq Age Sex Outcome Treatment
1 68 Required Intervention