M2A 38MM MOD HD+6MM NK NO SKRT
Report
- Report Number
- 0001825034-2014-05605
- Event Type
- Injury
- Date Received
- June 19, 2014
- Date of Event
- May 23, 2014
- Report Date
- November 6, 2014
- Manufacturer
- BIOMET ORTHOPEDICS
- Product Code
- KWA
- PMA / PMN Number
- PK011110
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- PHYSICIAN
Narratives
THE PRODUCT IDENTIFICATION NECESSARY TO REVIEW MANUFACTURING HISTORY WAS NOT PROVIDED. CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. DEVICE AVAILABILITY - THE DEVICE IS REPORTED TO BE AVAILABLE FOR EVALUATION; HOWEVER, IT HAS NOT BEEN RECEIVED BY BIOMET ORTHOPEDICS TO DATE. IN THE EVENT THAT THE DEVICE IS RECEIVED AND EVALUATED, A FOLLOW UP REPORT WILL BE SENT TO THE FDA TO PROVIDE RESULTS.
EXAMINATION OF RETURNED DEVICE FOUND NO EVIDENCE OF PRODUCT NON-CONFORMANCE. DURING THE MATERIAL ANALYSIS, IT WAS NOTED THE COMPONENT SHOWED EVIDENCE OF SUBLUXATION OF THE JOINT, SCRATCHING OF THE BEARING SURFACES AND MINOR TAPER FRETTING.
THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH. EVALUATION IN PROCESS BUT NOT YET COMPLETE. UPON COMPLETION OF EVALUATION, A FOLLOW UP REPORT WILL BE SENT TO THE FDA. CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, ¿MATERIAL SENSITIVITY REACTIONS.¿ THIS REPORT IS NUMBER 1 OF 2 MDR'S FILED FOR THE SAME EVENT (REFERENCE 1825034-2014-05605 AND 08359).
IT WAS REPORTED PATIENT UNDERWENT A TOTAL HIP ARTHROPLASTY ON (B)(6) 2005. SUBSEQUENTLY, PATIENT WAS REVISED ON (B)(6) 2014 ALLEGEDLY DUE TO ADVERSE REACTION TO METAL DEBRIS AND PERSONAL INJURY. THE MODULAR HEAD AND ACETABULAR CUP WERE REMOVED AND REPLACED.
IT WAS REPORTED PATIENT UNDERWENT A TOTAL HIP ARTHROPLASTY ON (B)(6) 2005. SUBSEQUENTLY, PATIENT WAS REVISED ON (B)(6) 2014 ALLEGEDLY DUE TO ADVERSE REACTION TO METAL DEBRIS AND PERSONAL INJURY. THE MODULAR HEAD AND ACETABULAR CUP WERE REMOVED AND REPLACED. ADDITIONAL INFORMATION REVEALED PRODUCT IDENTIFICATION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 360573 | M2A 38MM MOD HD+6MM NK NO SKRT | PROSTHESIS, HIP | KWA | BIOMET ORTHOPEDICS | N/A | 908470 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization| R |