FDA Adverse Event Malfunction Summary report: N

INOMAX DSIR (DELIVERY SYSTEM)

MDR report key: 3880036 · Received April 3, 2014

Report

Report Number
3004531588-2014-00010
Event Type
Malfunction
Date Received
April 3, 2014
Report Date
March 25, 2014
Manufacturer
IKARIA
Product Code
MRP
PMA / PMN Number
K061901
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
RESPIRATORY THERAPIST

Narratives

Additional Manufacturer Narrative · 1

THIS INITIAL NON-SERIOUS DEVICE CASE REPORT WAS RECEIVED ON (B)(6) 2014 FROM A RESPIRATORY THERAPIST (RT) IN THE UNITED STATES WHO CALLED TO REPORT A "FAULTY DISPLAY SCREEN" ON THE INOMAX DSIR DS20090537. THE DEVICE WAS NOT IN USE AT THE TIME OF THE DEVICE ISSUE. (COMPLAINT-(B)(4)). INVESTIGATION RESULTS COMPLETED ON (B)(4) 2014. CASE COMMENT: (B)(4) 2014: THIS DEVICE WAS NOT IN USE AT THE TIME OF DEVICE MALFUNCTION AND DID NOT RESULT IN AN ADVERSE EVENT; HOWEVER IT IS BEING REPORTED BECAUSE A SIMILAR MALFUNCTION OCCURRED IN THE PAST THAT RESULTED IN A SERIOUS ADVERSE EVENT (SEE MDR#3004531588-2013-00023). EVALUATION SUMMARY: THE INOMAX DSIR DS20090537 WAS RETURNED TO IKARIA'S REGIONAL SERVICE CENTER (RSC) FOR SERVICE EVALUATION. THE RSC INVESTIGATION CONFIRMED AND EXPERIENCED THE REPORTED COMPLAINT OF DISPLAY GOING BLANK. THE RSC REPLACED THE DISPLAY, SHROUD, AND BACKLIGHT INVERTER TO CORRECT THE PROBLEM. THE ROOT CAUSE FOR THIS INCIDENT IS DISPLAY - BACKLIGHT FAILURE.

Description of Event or Problem · 1

TOUCH SCREEN ON THE INOMAX DSIR BLANK AND NOT RESPONDING [DEVICE MALFUNCTION]. CASE DESCRIPTION: THIS INITIAL NON-SERIOUS DEVICE CASE REPORT WAS RECEIVED ON (B)(6) 2014 FROM A RESPIRATORY THERAPIST (RT) IN THE UNITED STATES WHO CALLED TO REPORT A "FAULTY DISPLAY SCREEN" ON THE INOMAX DSIR DS20090537. THE DEVICE WAS NOT IN USE AT THE TIME OF THE DEVICE ISSUE. IKARIA INVESTIGATION RESULTS WERE RECEIVED ON (B)(4) 2014. RELEVANT MEDICAL HISTORY/CO-MORBIDITIES: NO PATIENT. CONCOMITANT MEDICATIONS: NOT APPLICABLE. ACCORDING TO THE RT, ON (B)(6) 2014 "UPON START UP, THE MAIN SCREEN OF THE INOMAX DSIR DS 20090537 APPEARED FOR A FEW SECONDS THEN BURNED BLANK/BLACK." THE RT STATED THERE WAS "SLIGHT BACKLIGHT TO THE SCREEN MAKING IT ALMOST APPEAR PINK IN COLOR". THE RT CYCLED THE AC POWER TO STANDBY THEN ON HOWEVER THE TOUCH SCREEN ON THE INOMAX DSIR WAS NOT RESPONDING. THE DEVICE WAS NOT IN USE ON A PATIENT AT THE TIME OF THE DEVICE ISSUE. THE INOMAX DSIR DS20090537 WAS RETURNED TO IKARIA FOR INSPECTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
202499 INOMAX DSIR (DELIVERY SYSTEM) APPARATUS, NITRIC OXIDE DELIVERY MRP IKARIA 10007

Patients

Seq Age Sex Outcome Treatment
1