ZIMMER SKIN GRAFT MESHER COMPLETE
Report
- Report Number
- 1526350-2014-00322
- Event Type
- Malfunction
- Date Received
- April 24, 2014
- Date of Event
- April 1, 2014
- Report Date
- April 21, 2014
- Manufacturer
- ZIMMER SURGICAL
- Product Code
- GFD
- Removal / Correction Number
- RES 61798
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CT, US
- Reporter Occupation
- UNKNOWN
Narratives
ON MAY 31, 2012, US AND (B)(4) CUSTOMERS WERE SENT AN URGENT PATIENT SAFETY ADVISORY INFORMING THEM OF THE NEED FOR PROPER CARE AND PREVENTIVE MAINTENANCE OF THEIR DEVICE INFORMING THEM OF IMPROPERLY MAINTAINING INSTRUMENTS THAT MAY CAUSE DONOR SITE INJURIES OR RESULT IN DAMAGE TO THE GRAFT. THE DEVICE WAS RETURNED TO THE MANUFACTURER FOR REPAIR AND EVALUATION. THE SERVICE RECORD INDICATES THAT THE DEVICE WAS MANUFACTURED ON 03/03/2005 AND WAS LAST REPAIRED ON 12/15/2005 FOR AN UNKNOWN ISSUE. EVALUATION OF THE DEVICE OBSERVED THE COMB HAD SLIGHTLY BENT TINES ON THE RIGHT END. THE ROLLER HAD WORN GEAR TEETH AND THE RIGHT END WAS GNARLED. THE CUSTOMER RETURNED A CUTTER FOR EVALUATION IT HAD DAMAGE ALONG THE BLADES AND WEAR TO THE GEAR TEETH. THE SIDE PLATES WERE GOUGED AT THE ENTRY OF THE ROLLER AD AT THE EARS. THE CUSTOMER DID NOT RETURN A RATCHET FOR EVALUATION. PRIOR TO REPAIR, BOTH THE TEST MESH AND THE CALIBRATION CHECK COULD NOT BE PERFORMED DUE TO THE DAMAGED COMB. THE CUTTER DID NOT PASS CUTTER EVALUATION AND WAS RETURNED TO THE CUSTOMER AS NON-REPAIRABLE. REPAIR OF THE DEVICE INCLUDED REPLACEMENT OF THE COMB, ROLLER AND ROLLER GEAR, SIDE PLATES, BALL DETENTS, WASHERS AND SHOULDER BOLTS. THE DEVICE IS NINE YEARS OLD AND HAS NOT BEEN RETURNED FOR SERVICE AT ZIMMER SURGICAL IN OVER RIGHT YEARS; THEREFORE, LACK OF PREVENTATIVE MAINTENANCE AND IMPROPER HANDLING BY THE CUSTOMER MOST LIKELY CAUSED THE DAMAGE TO THE COMB OF THE DEVICE, WHICH LIKELY CAUSED THE CUSTOMER'S REPORTED EVENT. THE DEVICE WAS SERVICED AND RETURNED TO THE CUSTOMER.
IT WAS REPORTED THAT THE ZIMMER SKIN GRAFT MESHER COMPLETE WAS NOT MESHING CORRECTLY. THERE WAS NO PATIENT HARM OR DELAY REPORTED, AND THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE DEVICE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 248176 | ZIMMER SKIN GRAFT MESHER COMPLETE | ZIMMER SKIN GRAFT MESHER COMPLETE | GFD | ZIMMER SURGICAL | NA | NA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |