M2A-MAGNUM MOD HD SZ 46MM
Report
- Report Number
- 0001825034-2014-05487
- Event Type
- Injury
- Date Received
- June 12, 2014
- Date of Event
- October 19, 2012
- Report Date
- August 5, 2014
- Manufacturer
- BIOMET ORTHOPEDICS
- Product Code
- KWA
- PMA / PMN Number
- PK042037
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- ATTORNEY
Narratives
THIS FOLLOW-UP REPORT IS BEING FILED TO RELAY ADDITIONAL INFORMATION, WHICH WAS UNKNOWN AT THE TIME OF THE INITIAL MEDWATCH.
CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, "MATERIAL SENSITIVITY REACTIONS." NUMBER 6 STATES, "INADEQUATE RANGE OF MOTION DUE TO IMPROPER SELECTION OR POSITIONING OF COMPONENTS." NUMBER 14 STATES, "INTRAOPERATIVE OR POSTOPERATIVE BONE FRACTURE AND/OR POSTOPERATIVE PAIN." NUMBER 15 STATES, "ELEVATED METAL ION LEVELS HAVE BEEN REPORTED WITH METAL ON METAL ARTICULATING SURFACES." THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT A RIGHT TOTAL HIP ARTHROPLASTY ON (B)(6) 2006. PATIENT'S LEGAL COUNSEL REPORTED PATIENT WAS REVISED ON (B)(6) 2012 DUE TO PATIENT ALLEGATIONS OF PAIN, BONE/TISSUE DAMAGE, LOSS OF RANGE OF MOTION, ELEVATED METAL ION LEVELS AND METALLOSIS. THE MODULAR HEAD AND TAPER ADAPTER WERE REMOVED AND REPLACED. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF¿S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED.
LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT A RIGHT TOTAL HIP ARTHROPLASTY ON (B)(6) 2006. PATIENT'S LEGAL COUNSEL REPORTED PATIENT WAS REVISED ON (B)(6) 2012 DUE TO PATIENT ALLEGATIONS OF PAIN, BONE/TISSUE DAMAGE, LOSS OF RANGE OF MOTION, ELEVATED METAL ION LEVELS AND METALLOSIS. THE MODULAR HEAD AND TAPER ADAPTER WERE REMOVED AND REPLACED. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT, AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT MEDICAL RECORDS INDICATES THAT RIGHT HIP REVISION PROCEDURE PERFORMED ON (B)(6) 2012 WAS DUE TO PAIN, FATIGUE, ACHINESS, SWELLING, AND ELEVATED CHROMIUM AND COBALT LEVELS. THE PATIENT'S OPERATIVE REPORT NOTED A CYST. ADDITIONAL INFORMATION RECEIVED NOTED THAT ON (B)(6) 2012 PATIENT'S BLOOD WAS TESTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 348042 | M2A-MAGNUM MOD HD SZ 46MM | PROSTHESIS, HIP | KWA | BIOMET ORTHOPEDICS | N/A | 508000 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 59 YR | Hospitalization| R |