FDA Adverse Event Injury Summary report: N

M2A-MAGNUM MOD HD SZ 48MM

MDR report key: 3864966 · Received June 10, 2014

Report

Report Number
0001825034-2014-05414
Event Type
Injury
Date Received
June 10, 2014
Date of Event
March 20, 2013
Report Date
May 27, 2014
Manufacturer
BIOMET ORTHOPEDICS
Product Code
KWA
PMA / PMN Number
PK042037
Removal / Correction Number
N/A
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

CURRENT INFORMATION IS INSUFFICIENT TO PERMIT A CONCLUSION AS TO THE CAUSE OF THE EVENT. REVIEW OF DEVICE HISTORY RECORDS SHOW THAT LOT RELEASED WITH NO RECORDED ANOMALY OR DEVIATION. THERE ARE WARNINGS IN THE PACKAGE INSERT THAT STATE THAT THIS TYPE OF EVENT CAN OCCUR: UNDER POSSIBLE ADVERSE EFFECTS, NUMBER 1 STATES, "MATERIAL SENSITIVITY REACTIONS." NUMBER 4 STATES, ¿LOOSENING OR MIGRATION OF THE IMPLANTS MAY OCCUR DUE TO LOSS OF FIXATION, TRAUMA, MALALIGNMENT, BONE RESORPTION, EXCESSIVE ACTIVITY.¿ NUMBER 6 STATES, "INADEQUATE RANGE OF MOTION DUE TO IMPROPER SELECTION OR POSITIONING OF COMPONENTS." NUMBER 14 STATES, "INTRAOPERATIVE OR POSTOPERATIVE BONE FRACTURE AND/OR POSTOPERATIVE PAIN." NUMBER 15 STATES, "ELEVATED METAL ION LEVELS HAVE BEEN REPORTED WITH METAL ON METAL ARTICULATING SURFACES." THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PATIENT¿S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. THIS REPORT IS NUMBER 2 OF 2 MDRS FILED FOR THE SAME EVENT (REFERENCE 1825034-2014-00732 AND -05414).

Description of Event or Problem · 1

LEGAL COUNSEL FOR PATIENT REPORTED PATIENT UNDERWENT A LEFT TOTAL HIP ARTHROPLASTY ON (B)(6) 2008. SUBSEQUENTLY, PATIENT'S LEGAL COUNSEL REPORTED PATIENT WAS REVISED ON (B)(6) 2013 DUE TO PATIENT ALLEGATIONS OF PAIN, LOSS OF RANGE OF MOTION, BONE/TISSUE DAMAGE AND ELEVATED METAL ION LEVELS. REVIEW OF INVOICE HISTORY CONFIRMED THE MODULAR HEAD AND ACETABULAR CUP WERE REMOVED AND REPLACED. THIS REPORT IS BASED ON ALLEGATIONS SET FORTH IN PLAINTIFF'S COMPLAINT AND THE ALLEGATIONS CONTAINED THEREIN ARE UNVERIFIED. ADDITIONAL INFORMATION RECEIVED IN PATIENT¿S OPERATIVE (OP) NOTES DATED (B)(6) 2013 REPORTS PATIENT WAS REVISED DUE TO A LOOSE ACETABULAR COMPONENT. REVISION OP REPORT NOTES BENIGN, NORMAL-LOOKING SYNOVIAL FLUID; NO BONY INGROWTH OF THE ACETABULAR COMPONENT; AND THE PRESENCE OF SCLEROTIC BONE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
339555 M2A-MAGNUM MOD HD SZ 48MM PROSTHESIS, HIP KWA BIOMET ORTHOPEDICS N/A 220490

Patients

Seq Age Sex Outcome Treatment
1 Hospitalization| R