FDA Adverse Event Injury Summary report: N

AORTIC AP

MDR report key: 3807749 · Received May 13, 2014

Report

Report Number
2134151-2014-00020
Event Type
Injury
Date Received
May 13, 2014
Date of Event
January 4, 2014
Report Date
October 27, 2014
Manufacturer
MEDTRONIC ATS MEDICAL
Product Code
LWQ
PMA / PMN Number
P990046
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE DEVICE HISTORY RECORD WAS REVIEWED AND SHOWED THAT THIS PRODUCT MET ALL MANUFACTURING SPECIFICATIONS FOR PRODUCT RELEASED FOR DISTRIBUTION. NO ISSUES WERE IDENTIFIED THAT WOULD HAVE IMPACTED THIS EVENT. THE COMPLAINT INFORMATION WAS REPORTED FROM A JOURNAL ARTICLE THAT INVOLVED SEVEN PATIENTS WITH PROSTHETIC VALVE DYSFUNCTION (PVD). THE AVAILABLE INFORMATION DOES NOT INDICATE WHICH ISSUES EACH OF THESE DEVICES SPECIFICALLY EXPERIENCED. NO DEVICES HAVE BEEN RETURNED FOR ANALYSIS. BASED ON THE AVAILABLE INFORMATION, A ROOT CAUSE COULD NOT BE DETERMINED.

Additional Manufacturer Narrative · 1

SUBSEQUENTLY, MEDTRONIC RECEIVED ADDITIONAL DETAILS IDENTIFYING THIS DEVICE¿S SERIAL NUMBER, PATIENT AGE, GENDER AND POST-IMPLANT TIME TO THE IDENTIFICATION OF THE VALVE OBSTRUCTION (APPROXIMATELY 116 MONTHS). NO OTHER DETAILS WERE PROVIDED THAT DESCRIBED THE SPECIFIC DEVICE ISSUES OR OUTCOMES FOR THIS DEVICE/PATIENT, INCLUDING THE CURRENT STATUS/LOCATION OF THE DEVICE. IT WAS REPORTED THAT THE PATIENT RECOVERED, WITH NO REPORT OF SUBSEQUENT ADVERSE EFFECTS. A SUPPLEMENTAL REPORT WILL BE FILED IF ADDITIONAL INFORMATION IS RECEIVED OR WHEN THE INVESTIGATION IS COMPLETE. EVALUATION OF ADVANCING THE STANDARD VALVE DYSFUNCTION BY MULTIDETECTOR-ROW CT TESHIMA HIDEKI, S. AOYAGI, T. UEDA, K. TAKAGI, T. SHOJIMA, H. TANAKA J ARTIF ORGANS 2014 DOI 10.1007/S10047-013-0751-Z. (B)(4).

Additional Manufacturer Narrative · 1

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

MEDTRONIC ORIGINALLY SUBMITTED MEDWATCH REPORT 2134151-2014-00016 FOR A MEDICAL JOURNAL ARTICLE THAT INCLUDED THIS DEVICE-PATIENT ISSUE AS PART OF THE FOLLOWING SUMMARY: MEDTRONIC RECEIVED INFORMATION THAT FIVE PATIENTS WHO HAD RECEIVED REPLACEMENT MECHANICAL HEART VALVES LATER UNDERWENT REOPERATION DUE TO OBSTRUCTION OF THE PROSTHETIC VALVES. THE INFORMATION WAS CONTAINED IN A LITERATURE ARTICLE THAT EVALUATED THE DIAGNOSTIC USE OF ELECTROCARDIOGRAPHICALLY GATED MULTI-DETECTOR ROW COMPUTED TOMOGRAPHY (MDCT) AS A COMPLEMENT TO ECHOCARDIOGRAPHY AND CINERADIOGRAPHY DIAGNOSIS FOR PROSTHETIC VALVE DYSFUNCTION (PVD) OF MECHANICAL HEART VALVES. IT WAS REPORTED THAT AN MDCT EVALUATION WAS PERFORMED ON A SUBSET OF 24 PATIENTS FROM 270 PATIENTS WHO RECEIVED A REPLACEMENT MECHANICAL HEART VALVE OVER AN EIGHT-YEAR PERIOD BETWEEN 1997 AND 2005 AT A SINGLE HOSPITAL, AND WERE FOLLOWED ON AN ANNUAL BASIS WITH ROUTINE TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) AND CINERADIOGRAPHY ON AN OUTPATIENT BASIS. THE TEE AND CINERADIOGRAPHY RESULTS OF THE 24 PATIENTS SHOWED NORMAL VALVE FUNCTION IN 17 PATIENTS AND PROSTHETIC VALVE DYSFUNCTION (PVD) IN SEVEN. THE FINDINGS OF PVD INCLUDED AORTIC PROSTHETIC VALVE OBSTRUCTION IN FOUR PATIENTS, AN AORTIC ANNULAR ANEURYSM WITH PARAPROSTHETIC REGURGITATION IN ONE, AND A BLOCKED LEAFLET IN THE MITRAL POSITION IN TWO. A TOTAL OF 30 VALVES, INCLUDING 23 AORTIC VALVES, 6 MITRAL VALVES, AND ONE TRICUSPID VALVE, WERE SUBSEQUENTLY EVALUATED VIA MDCT. THOSE EVALUATIONS REVEALED A SUB-PROSTHETIC MASS (EXTENDING FROM STRUCTURES ADJACENT TO THE VALVE INTO THE VALVE ORIFICE) IN ALL FIVE PATIENTS WITH PVD (AND IN FOUR PATIENTS WITH NORMAL VALVE FUNCTION IN THE AORTIC POSITION), AND ONE INSTANCE OF AN ANNULAR ANEURYSM. THE MDCT RESULTS ALSO SHOWED TWO PATIENTS WITH VALVULAR MASSES AND MITRAL PVD. THROMBOLYTIC THERAPY FOR THE SUB-PROSTHETIC MASS WAS ATTEMPTED IN THREE OF THE FIVE PATIENTS, BUT NO RESPONSE TO THE THERAPY WAS OBSERVED. OF THE SEVEN PATIENTS WITH ATRIAL OR MITRAL PVD, FIVE UNDERWENT REOPERATION AFTER THE MDCT EVALUATION (TWO PATIENTS DECLINED REOPERATION). AT REOPERATION, SUB-PROSTHETIC PANNUS IN THE AORTIC POSITION WAS OBSERVED IN TWO PATIENTS, SUB-PROSTHETIC PANNUS AND AN ANNULAR ANEURYSM WITH PARAPROSTHETIC LEAKS WERE OBSERVED IN ONE PATIENT, AND MITRAL VALVE THROMBOSIS WAS OBSERVED IN TWO PATIENTS, CONFIRMING THE FINDINGS OBSERVED ON MDCT. THE ANNULAR ANEURYSM WAS OBSERVED IN A PATIENT WHO HAD HEALED INFECTIVE ENDOCARDITIS. THE ARTICLE DID NOT REPORT ANY SUBSEQUENT ADVERSE PATIENT EFFECTS FOR THE PATIENTS WHO UNDERWENT REOPERATION OR THE PATIENTS WHO DECLINED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
286233 AORTIC AP HEART-VALVE, MECHANICAL LWQ MEDTRONIC ATS MEDICAL 501DA18

Patients

Seq Age Sex Outcome Treatment
1 00061 YR Required Intervention