PLATE, FIXATION, BONE
Report
- Report Number
- 2520274-2014-10263
- Event Type
- Malfunction
- Date Received
- March 14, 2014
- Report Date
- February 16, 2014
- Manufacturer
- SYNTHES (USA)
- Product Code
- HRS
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. ARORA, R. ET AL (2012). BEHAVIOUR OF CHRONOS INJECT IN METAPHYSEAL BONE DEFECTS OF DISTAL RADIUS FRACTURES: TISSUE REACTION AFTER 6-15 MONTHS. INJURY, INT. J. CARE INJURED, 43, 1683-1688. THIS REPORT IS FOR AN UNKNOWN 2.4 MILLIMETER LOCKING COMPRESSION PLATE DISTAL RADIUS PLATE. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING JOURNAL ARTICLE: ARORA, R. ET AL (2012). BEHAVIOUR OF CHRONOS INJECT IN METAPHYSEAL BONE DEFECTS OF DISTAL RADIUS FRACTURES: TISSUE REACTION AFTER 6-15 MONTHS. INJURY, INT. J. CARE INJURED, 43, 1683-1688. THE AUTHORS STUDIED SIX PATIENTS (THREE MEN AND THREE WOMEN) WITH A MEAN AGE OF 70 YEARS (RANGE, 62-81 YEARS) BETWEEN 2006 AND 2008 WITH A DORSALLY DISPLACED DISTAL RADIUS FRACTURE WHO WERE TREATED WITH SYNTHES CHRONOS INJECT APPLICATION INTO THE METAPHYSEAL BONE DEFECT AND OPEN REDUCTION AND A VOLAR LOCKING PLATE, SYNTHES 2.4 MILLIMETER LOCKING COMPRESSION PLATE (LCP) DISTAL RADIUS PLATE. DURING IMPLANT REMOVAL (AVERAGE 11 MONTHS), A TWO MILLIMETER DIAMETER BIOPSY WAS OBTAINED FROM THE REGION OF THE PREVIOUS CEMENT INJECTION FOR EVALUATION. TWO PATIENTS REQUIRED IMPLANT REMOVAL DUE TO FLEXOR TENDON IRRITATION. A 70 YEAR OLD MALE EXPERIENCED LOSS OF REDUCTION POST-OPERATIVELY DUE TO A HIGHLY COMMINUTED AND UNSTABLE SITUATION WHICH COULD NOT BE NEUTRALIZED WITH THE LOCKING PLATE RESULTING IN A DORSAL TILT OF 25 DEGREES. THE AUTHORS REPORTED THAT SMALL AMOUNTS OF CHRONOS INJECT WERE DETECTABLE IN HUMAN PATIENTS 15 MONTHS AFTER IMPLANTATION INTO A DISTAL RADIUS BONE DEFECT, INDICATING CHRONOS INJECT WAS INTEGRATED INTO THE NEWLY FORMED TRABECULAR BONE NETWORK. THIS IS A SERIOUS INJURY/REPORTABLE MALFUNCTION REPORT FOR ONE PATIENT: A (B)(6) MALE EXPERIENCED LOSS OF REDUCTION POST-OPERATIVELY DUE TO A HIGHLY COMMINUTED AND UNSTABLE SITUATION WHICH COULD NOT BE NEUTRALIZED WITH THE LOCKING PLATE RESULTING IN A DORSAL TILT OF 25 DEGREES. THIS IS REPORT 2 OF 2 FOR COMPLAINT COM¿041625. THIS REPORT IS FOR AN UNKNOWN 2.4 MILLIMETER LCP DISTAL RADIUS PLATE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 152813 | PLATE, FIXATION, BONE | HRS | SYNTHES (USA) |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 70 YR | Required Intervention |