DA VINCI SURGICAL SYSTEM
Report
- Report Number
- 2955842-2014-01519
- Event Type
- Injury
- Date Received
- March 14, 2014
- Report Date
- February 26, 2014
- Manufacturer
- INTUITIVE SURGICAL,INC.
- Product Code
- NAY
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL
- Reporter Occupation
- PHYSICIAN
Narratives
BASED ON THE INFORMATION PROVIDED, INTUITIVE SURGICAL INC. (ISI) HAS NOT DETERMINED THE ROOT CAUSE FOR THE PLEURAL INJURY DURING THE DA VINCI PROCEDURE. THE JOURNAL ARTICLE DOES NOT CONTAIN ANY ALLEGATION THAT A MALFUNCTION OF A DA VINCI SYSTEM, INSTRUMENT OR ACCESSORY OCCURRED IN THE REPORTED PROCEDURE. ISI HAS ATTEMPTED TO CONTACT THE SITE TO OBTAIN ADDITIONAL INFORMATION CONCERNING THE REPORTED EVENT; HOWEVER, NO ADDITIONAL INFORMATION HAS BEEN PROVIDED AS OF THE DATE OF THIS REPORT. A FOLLOW-UP MDR WILL BE SUBMITTED IF ADDITIONAL INFORMATION IS RECEIVED. THIS COMPLAINT IS BEING REPORTED DUE TO THE FOLLOWING CONCLUSION: THE JOURNAL ARTICLE INDICATED THAT A PATIENT SUFFERED A PLEURAL INJURY DURING THE DA VINCI PROCEDURE. THIS REPORT DOES NOT ADMIT THAT THE REPORT OR INFORMATION SUBMITTED UNDER THIS REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, INTUITIVE SURGICAL OR INTUITIVE SURGICAL EMPLOYEES, CAUSED OR CONTRIBUTED TO THE REPORTABLE EVENT.
ON (B)(4) 2014, INTUITIVE SURGICAL INC. (ISI) REVIEWED A JOURNAL ARTICLE BY RUPA SEETHARAMAIAH ET AL. TITLED ROBOTIC REPAIR OF GIANT PARAESOPHAGEL HERNIAS. ACCORDING TO THE REPORTED ARTICLE, A (B)(6) HEALTHY WOMAN CAME TO THE EMERGENCY DEPARTMENT WITH SHORTNESS OF BREATH. PEH WAS DIAGNOSED, AND THE PATIENT WAS TAKEN TO THE OPERATING ROOM. DURING THE PROCEDURE, A GPEH WAS FOUND AND THE STOMACH WAS STRONGLY ADHERED TO BOTH THE RIGHT AND LEFT CRUS. DURING THE DISSECTION, A PLEURAL INJURY WAS NOTICED. REDUCTION WAS COMPLETED, THE PLEURAL INJURY WAS REPAIRED WITH NO. 3-0 VICRYL (ETHICON), AND THE HERNIA WAS CLOSED WITH NONABSORBABLE SUTURE. NO PLEURAL TUBE WAS USED. A BIOLOGICAL MESH WAS PLACED AND A NISSEN FUNDOPLICATION PERFORMED. THE TOTAL PROCEDURE WAS COMPLETED IN 258 MINUTES, AND THE PATIENT WAS DISCHARGED 3 DAYS LATER. THE HOSPITAL NAME AND THE DA VINCI SERIAL NUMBER INVOLVED WITH THIS PATIENT WAS NOT PROVIDED IN THE ARTICLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 153995 | DA VINCI SURGICAL SYSTEM | ENDOSCOPIC INSTRUMENT CONTROL SYSTEM | NAY | INTUITIVE SURGICAL,INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 69 YR | Required Intervention |