FDA Adverse Event Injury Summary report: N

2520274-2014-00857

MDR report key: 3648461 · Received February 26, 2014

Report

Report Number
2520274-2014-00857
Event Type
Injury
Date Received
February 26, 2014
Report Date
January 31, 2014
Manufacturer
SYNTHES USA
Product Code
MQV
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
PA
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DEVICE IS USED FOR TREATMENT, NOT DIAGNOSIS. DATE OF EVENT: J NEUROSURG SPINE 12:221¿231, 2010. DEVICE IS AN UNKNOWN CHRONOS, QUANTITY 1. INVESTIGATION COULD NOT BE COMPLETED, NO CONCLUSION COULD BE DRAWN AS NO DEVICE WAS RETURNED AND NO LOT NUMBER WAS PROVIDED. MANUFACTURING RECORDS COULD NOT BE REVIEWED WITHOUT A LOT NUMBER.

Description of Event or Problem · 1

JOURNAL ARTICLE RECEIVED: EARLY EXPERIENCE TREATING THORACIC DISC HERNIATIONS USING A MODIFIED TRANSFACET PEDICLE-SPARING DECOMPRESSION AND FUSION; RICHARD BRANSFORD, FANGYI ZHANG, CARLO BELLABARBA, MARK KONODI, AND JENS R. CHAPMAN; J NEUROSURG; DEPARTMENT OF ORTHOPAEDICS AND SPORTS MEDICINE, HARBORVIEW MEDICAL CENTER AND DEPARTMENT OF NEUROSURGERY, UNIVERSITY OF WASHINGTON.: J NEUROSURG SPINE 12:221¿231, 2010; REPORTED: THE OBJECTIVE OF THIS STUDY WAS TO ASSESS OUTCOMES AND COMPLICATIONS IN A CONSECUTIVE SERIES OF PATIENTS WITH THORACIC DISC HERNIATIONS UNDERGOING POSTERIOR TRANSFACET DECOMPRESSION AND DISCECTOMY WITH POSTERIOR INSTRUMENTATION AND FUSION. SEGMENTAL FIXATION WAS PERFORMED WITH THE UNIVERSAL SPINE SYSTEM (SYNTHES). INTERBODY ARTHRODESIS WAS ACCOMPLISHED WITH MACHINED FREEZE-DRIED ALLOGRAFT T-PLIF SPACERS (SYNTHES). THE AVERAGE T-PLIF HEIGHT WAS 9MM (RANGE 7-15MM). ARTHRODESIS WAS CARRIED OUT WITH A MIXTURE OF LOCAL BONE GRAFT DERIVED FROM THE NEURAL ELEMENT DECOMPRESSION, TRICALCIUM PHOSPHATE PELLETS (CHRONOS, SYNTHES), DEMINERALIZED BONE MATRIX ALLOGRAFT (DBX, SYNTHES), AND AUTOLOGOUS BLOOD. CARE WAS TAKEN TO ENSURE THAT APPROXIMATELY HALF OF THE GRAFT MATERIAL WAS COMPOSED OF MORCELLIZED LOCAL BONE GRAFT. RESULTS: EIGHTEEN CONSECUTIVE PATIENTS WITH 29 SYMPTOMATIC THORACIC DISC HERNIATIONS WERE TREATED WITH A MODIFIED TRANSFACETAL, PEDICLE-SPARING DECOMPRESSION AND SEGMENTAL RECONSTRUCTION AND FUSION. THE MEAN AGE OF THE PATIENTS WAS 50 YEARS (RANGE 27-71 YEARS) AND 11 OF 18 WERE MEN. THREE PATIENTS HAD POSTOPERATIVE INFECTIONS. IN ALL 3 CASES, PROLONGED POSTOPERATIVE WOUND DRAINAGE REQUIRED REOPERATION DESPITE APPROPRIATE PREOPERATIVE AND POSTOPERATIVE INTRAVENOUS ANTIBIOTIC THERAPY. EACH PATIENT HAD POSITIVE BACTERIAL CULTURES AND RESPONDED SUCCESSFULLY TO OPERATIVE IRRIGATION AND DEBRIDEMENT AND APPROPRIATE ANTIBIOTIC THERAPY. AN ADDITIONAL PATIENT DEVELOPED A LARGE SEROMA THAT REQUIRED PERCUTANEOUS DRAINAGE UNDER CT GUIDANCE. IN ANOTHER PATIENT, POSTOPERATIVE IMAGING REVEALED AN EXCESSIVELY LONG SCREW AT T-6 IN CLOSE PROXIMITY TO THE AORTA. THIS PATIENT ALSO HAD A SUBOPTIMALLY PLACED ALLOGRAFT SPACER WITHIN THE T6-7 DISC SPACE AND UNDERWENT AN UNEVENTFUL REOPERATION FOR REPOSITIONING OF THE LEFT T-6 SCREW AND THE T6-7 ALLOGRAFT SPACER ON THE SECOND POSTOPERATIVE DAY; HE WAS SUBSEQUENTLY DISCHARGED 8 DAYS AFTER HIS ORIGINAL SURGERY. TWO OF THE THREE PATIENTS WHO DEVELOPED POST-OPERATIVE INFECTIONS WERE AT INCREASED RISK DUE TO MORBID OBESITY WITH BODY MASS INDEX GREATER THAN 35. ANOTHER PATIENT WAS AT INCREASED RISK DUE TO POORLY CONTROLLED DIABETES. CONCLUSION: A MODIFIED TRANSFACETAL PEDICLE-SPARING APPROACH COMBINED WITH SHORT SEGMENTAL FUSION OFFERS A SAFE MEANS OF ACHIEVING CONCURRENT DECOMPRESSION AND SEGMENTAL STABILIZATION AND IS AN OPTION FOR CERTAIN SUBTYPES OF THORACIC DISC HERNIATION. ALTHOUGH 5 PATIENTS REQUIRED ADDITIONAL SURGERY FOR POSTOPERATIVE COMPLICATIONS, ALL PATIENTS EXPERIENCED IMPROVEMENT RELATIVE TO THEIR PREOPERATIVE STATUS. THIS REPORT IS FOR AN UNKNOWN CHRONOS. THIS REPORT IS 6 OF 6 FOR COMPLAINT 74912. A COPY OF THE LITERATURE ARTICLE IS BEING SUBMITTED WITH THIS MEDWATCH.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
117839 MQV SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention