FDA Adverse Event Injury Summary report: N

PATTERSON DENTAL

MDR report key: 362834 · Received November 23, 2001

Report

Report Number
MW1023497
Event Type
Injury
Date Received
November 23, 2001
Date of Event
September 1, 2001
Report Date
November 1, 2001
Manufacturer
*
Product Code
EMG
Product Problem
Yes
Report Source
Voluntary report
Reporter Location
NM, US
Reporter Occupation
DENTIST

Narratives

Description of Event or Problem · 1

ADD'L INFO REC'D FROM MFR 2/14/02: THE PRODUCT REFERENCED IN MEDWATCH FORM, REF NUMBER 1023497 IS MFG FOR PATTERSON DENTAL CO BY DENTAFIX UK LTD, UNITS 11, 12, 13 HELIX, BUSINESS PARK WILTON RD, SURREY, ENGLAND. PATTERSON IS MERELY A DISTRIBUTOR OF THE PRODUCT, AND DOES NOT ALTER, CHANGE OR REPACKAGE THE PRODUCT. THEY BELIEVE PRIMARY RESPONSIBILITY RESTS WITH THE MFR. AS A GENERAL PROCEDURE, HOWEVER, WHENEVER THEY RECEIVE A REPORT INVOLVING PRODUCT FAILURE, THEY INVESTIGATE THE INCIDENT AND ATTEMPT TO RETRIEVE THE PRODUCT AND HAVE IT TESTED. DUE TO THE ANONYMITY OF THE RPTR, A FULL INVESTIGATION OF THIS MATTER, INCLUDING RETRIEVAL OF THE PRODUCT FOR TESTING PURPOSES HAS NOT BEEN POSSIBLE.

Description of Event or Problem · 1

RPTR WAS EXTRACTING TOOTH # 14 ON A SEVERELY DEVELOPMENTALLY DISABLED CHILD. RPTR WAS USING PATTERSON DENTAL BRAND OF FORCEPS #1505. AS RPTR PUT THE FORCEPS ON THE TOOTH THE BEAK OF THE FORCEPS BROKE AND FELL DOWN THE PT'S THROAT. RPTR IMMEDIATELY GRABBED THE CHILD AND HELD THEM SO THEIR HEAD WAS THE LOWEST PART OF THEIR BODY. THE BROKEN PORTION WAS COUGHED OUT. A SECOND 1505 BROKE IN THE SAME SPOT WHILE BEING CLEANED. A THIRD FORCEPS OF THE SAME SIZE AND BRAND WAS REPORTED TO HAVE BROKEN AT ONE OF RPTR'S OFFICES.

Description of Event or Problem · 1

ADD'L INFO RECEIVED FROM MFR 12-28-2001: PATTERSON DENTAL COMPANT DOES NOT MFR THIS PARTICULAR INSTRUMENT. THIS INSTRUMENT IS MANUFACTURED BY DENFIX UK LTD UNITS 11,12,13 HELIX, BUSINESS PARK WILTON ROAD, SURREY, ENGLAND. IF A SAMPLE OF THE FORCEPS WAS SUBMITTED THEY WOULD LIKE TO RETRIEVE THEM FOR THE MFR TO PERFORM TESTING.

Description of Event or Problem · 1

ADD'L INFO RECEIVED FROM MFR 4/15/02: THE PRODUCT REFERENCED IN MEDWATCH FROM IS MANUFACTURED FOR PATTERSON DENTAL COMPANY BY DENTAFIX UK LTD, UNITS 11,12,13 HELIX, BUSINESS PARK WILTON ROAD, SURREY, ENGLAND. PATTERSON IS MERELY A DISTRIBUTOR OF THE PRODUCT, AND DOES NOT ALTER, CHANGE OR REPACKAGE THE PRODUCT. THEY BELIEVE PRIMARY RESPONSIBILITY RESTS WITH THE MFR. AS A GENERAL PROCEDURE, HOWEVER, WHENEVER CO RECEIVES A REPORT INVOLVING PRODUCT FAILURE, THE CO INVESTIGATES THE INCIDENT AND ATTEMPTS TO RETRIEVE THE PRODUCT AND HAVE IT TESTED. DUE TO THE ANONYMITY OF THE REPORTER, A FULL INVESTIGATION OF THIS MATTER, INCLUDING RETRIEVAL OF THE PRODUCT FOR TESTING PURPOSES HAS NOT BEEN POSSIBLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
53122 PATTERSON DENTAL DENTAL FORCEPS #1505 EMG * 1505 *

Patients

Seq Age Sex Outcome Treatment
1 6 YR Required Intervention