FDA Adverse Event Malfunction Summary report: N

HOOK CEV390C DIA 3.5MM 330MM MONOPOLAR

MDR report key: 3607397 · Received February 5, 2014

Report

Report Number
9680837-2014-00006
Event Type
Malfunction
Date Received
February 5, 2014
Date of Event
December 23, 2013
Report Date
December 23, 2013
Manufacturer
XOMED MICROFRANCE MFG
Product Code
GEI
PMA / PMN Number
K993655
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THIS DEVICE IS USED FOR THERAPEUTIC PURPOSES. CONCOMITANT MEDICAL PRODUCTS: HOOK CEV390B DIA 3.5MM 330MM MONOPOLAR, 510K: K993655, LOT# 110103, MFR DATE JAN. 2011. DISSECTOR INSERT CEV398I 310MM DIA35, 510K: K993655, LOT# 130401, MFR DATE APR. 2013. SCISSORS INSERT CEV393I 310MM SERRATED, 510K: K993655, LOT# 130303, MFR DATE MAR. 2013. FENESTRATED INSERT CEV395I 310MM DIA35, 510K: K993655, LOT# 130303, MFR DATE MAR. 2013. (B)(4). THE PRODUCT ANALYSIS DETERMINED THAT: HOOK CEV390B DIA 3.5MM 330MM MONOPOLAR- ¿THE COATING SHRUNK IN LENGTH ON THE PROXIMAL PART OF THE INSTRUMENT. THE INSULATION DEFECT IS LOCATED ON THE PROXIMAL END OF THE DEVICE AND THE RISK OF ELECTRICAL INJURIES IS REMOTE.¿ HOOK CEV390C DIA 3.5MM 330MM MONOPOLAR- ¿THE COATING SHRUNK IN LENGTH ON THE DISTAL PART OF THE INSTRUMENT. THE DEFECT IS EASILY OBSERVABLE AND THE INSTRUMENT WAS PROBABLY NOT USED IN THIS CONDITION.¿ DISSECTOR INSERT CEV398I 310MM DIA35- ¿THE COATING SHRUNK IN LENGTH ON THE PROXIMAL PART OF THE INSTRUMENT. THE INSULATION DEFECT IS LOCATED ON THE PROXIMAL END OF THE DEVICE AND THE RISK OF ELECTRICAL INJURIES IS REMOTE.¿ SCISSORS INSERT CEV393I 310MM SERRATED- ¿THE COATING SHRUNK IN LENGTH ON THE DISTAL PART OF THE INSTRUMENT. THE DEFECT IS EASILY OBSERVABLE AND THE INSTRUMENT WAS PROBABLY NOT USED IN THIS CONDITION.¿ FENESTRATED INSERT CEV395I 310MM DIA35- ¿THE COATING SHRUNK IN LENGTH ON THE PROXIMAL PART OF THE INSTRUMENT. THE INSULATION DEFECT IS LOCATED ON THE PROXIMAL END OF THE DEVICE AND THE RISK OF ELECTRICAL INJURIES IS REMOTE.¿

Description of Event or Problem · 1

IT WAS REPORTED THAT A SALES REP RETURNED HIS INSTRUMENTS FOR REPAIR. THE REPAIR REPORT INDICATED A BREACH OF INSULATION IN THE ELECTROCAUTERY DEVICES.