FDA Adverse Event Injury Summary report: N

ENDURANT

MDR report key: 3591726 · Received January 24, 2014

Report

Report Number
2953200-2014-00114
Event Type
Injury
Date Received
January 24, 2014
Report Date
December 31, 2013
Manufacturer
MEDTRONIC IRELAND
Product Code
MIH
PMA / PMN Number
P100021
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

(B)(4). RESULTS: ENDOLEAK, CLAUDICATION, HEMATOMA, ARRHYTHMIA. TYPE II ENDOLEAK. CAUSE IS UNKNOWN. CONCLUSION: TYPE II ENDOLEAK. CAUSE IS UNKNOWN.

Description of Event or Problem · 1

MEDTRONIC RECEIVED THE FOLLOWING INFORMATION OBTAINED FROM THE JOURNAL ARTICLE ENTITLED; AMBULATORY PERCUTANEOUS ENDOVASCULAR ABDOMINAL AORTIC ANEURYSM REPAIR. HASAN H. DOSLUOGLU, MD, PURANDATH LALL, MBBS,RAPHAEL BLOCHLE, MD,LINDA M. HARRIS, MD, AND MACIEJ L. DRYJSKI, MD. (J VASC SURG 2014;59:58-64.) ANEURYSM AND VESSEL MORPHOLOGY NOT REPORTED. ON AN UNKNOWN DATE AN ENDURANT STENT GRAFT SYSTEM WAS IMPLANTED IN THE PATIENT FOR THE ENDOVASCULAR TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM. OBJECTIVE: PERCUTANEOUS ENDOVASCULAR ABDOMINAL AORTIC ANEURYSM REPAIR (PEVAR) HAS BEEN ASSOCIATED WITH FEWER GROIN WOUND COMPLICATIONS AND SHORTER OPERATIVE TIMES, BUT SAME-DAY DISCHARGE (SDD) HAS NOT BEEN REPORTED. THE GOAL OF OUR ARTICLE IS TO ASSESS THE FEASIBILITY AND SAFETY OF AMBULATORY PEVAR AND IDENTIFY PATIENT CHARACTERISTICS THAT ARE ELIGIBLE FOR THIS APPROACH. METHODS: CONSECUTIVE PATIENTS WHO UNDERWENT ELECTIVE ENDOVASCULAR ABDOMINAL AORTIC ANEURYSM REPAIR (EVAR) BETWEEN MARCH 2011 AND DECEMBER 2012 WERE REVIEWED. SDD WAS DISCUSSED DURING THE PREOPERATIVE VISIT WITH PATIENTS WHO WERE FUNCTIONALLY INDEPENDENT, WITHOUT SIGNIFICANT COMORBIDITIES, AND HAD FAVORABLE ANATOMY. THESE PATIENTS WERE GIVEN THE OPTION TO BE DISCHARGED IN THE EVENING OF THE PEVAR AFTER 6 HOURS OF BED REST IF THE PROCEDURE WAS UNEVENTFUL. CAUSES FOR DISCHARGE DELAY AND EARLY OUTCOMES WERE ANALYZED. RESULTS: DURING THE STUDY PERIOD, 79 PATIENTS UNDERWENT ABDOMINAL AORTIC ANEURYSM (AAA) REPAIR, 64 OF WHOM (MEAN AGE,70.269.9; RANGE, 59-97) HAD ELECTIVE EVAR (3 RUPTURES, 5 ACUTE PRESENTATIONS, 3 FENESTRATED EVARS, 4 ELECTIVE OPEN AAA REPAIRS WERE EXCLUDED). FIFTY-THREE PATIENTS (83%) HAD BILATERAL PERCUTANEOUS ACCESS, SEVEN HAD UNILATERAL PERCUTANEOUS (11%) ACCESS, AND THE REMAINING FOUR (6%) HAD BILATERAL FEMORAL ENDARTERECTOMIES. THE PERCUTANEOUS CLOSURE SUCCESS RATE WAS 96% IN 113 ATTEMPTS (THREE CONVERSIONS FOR INADEQUATE HEMOSTASIS, ONE FOR INABILITY TO DEPLOY DEVICE).MEAN LENGTH OF STAY WAS 1.36 1.4 DAYS (MEDIAN, 1 DAY) WITH NO 30-DAY MORTALITY. TWENTY-ONE PATIENTS (33%) WERE DISCHARGED THE SAME DAY (SDD GROUP), 24 (37%) ON POSTOPERATIVE DAY (POD) 1, 16 (25%) ON POD 2/3, AND 3 (5%) STAYED $4 DAYS. ONE PATIENT IN THE SDD GROUP WAS READMITTED ON POD 3 AFTER EVAR FOR SEVERE POSTIMPLANTATION SYNDROME. OF THE 23 PATIENTS WHO WERE DISCHARGED ON POD 1, 10 WERE KEPT OVERNIGHT DUE TO SEVERE CHRONIC OBSTRUCTIVE PULMONARY DISEASE, CORONARY ARTERY DISEASE, OR ADVANCED AGE, THREE TRANSPORTATION ISSUES, TWO INABILITY TO VOID, TWO PATIENT PREFERENCE, TWO FOR RENAL PROTECTION, AND FOUR DUE TO UNPLANNED FEMORAL CUTDOWN. PATIENTS IN THE SDD GROUP WERE SIGNIFICANTLY YOUNGER (66.5 6 5.4 YEARS VS 72.0 6 10.6 YEARS; P[ .029), HAD SMALLER AAAS (5.3 6 0.5 CM VS 5.9 6 1.0 CM; P [ .013), LESS BLOOD LOSS (115 6 90 ML VS 232 6 198 ML; P[.012), AND SHORTER OPERATING TIME (79624 MINUTES VS 121673 MINUTES ;P[.013). THERE WERE FEWER AMERICAN SOCIETY OF ANESTHESIOLOGISTS 4 PATIENTS IN THE SDD GROUP (24% VS 48%; P[.056). THE MAJORITY (81%) OF PATIENTS IN ALL GROUPS HAD GENERAL ANESTHESIA (86% VS 79% SDD VS OTHERS; P[.523). CONCLUSIONS: AMBULATORY PEVAR WAS FOUND TO BE FEASIBLE AND SAFE IN ONE-THIRD OF PATIENTS UNDERGOING ELECTIVE EVAR WHO DID NOT HAVE EXCESSIVE MEDICAL RISK, HAD GOOD FUNCTIONAL CAPACITY, AND UNDERWENT AN UNEVENTFUL PROCEDURE. THE IMPACT OF SDD ON COST-EFFECTIVENESS NEEDS TO BE FURTHER ASSESSED AND MAY NOT BE FEASIBLE IN HOSPITALS REIMBURSED BASED ON ADMISSION STATUS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
56551 ENDURANT SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH MEDTRONIC IRELAND

Patients

Seq Age Sex Outcome Treatment
1