TALENT
Report
- Report Number
- 2953200-2013-02535
- Event Type
- Death
- Date Received
- December 24, 2013
- Date of Event
- November 4, 2011
- Report Date
- December 2, 2013
- Manufacturer
- MEDTRONIC CARDIOVASCULAR
- Product Code
- MIH
- PMA / PMN Number
- P070027
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). EVALUATION, RESULTS: INHERENT RISK OF PROCEDURE (MIGRATION, ENDOLEAK, ANEURYSM RUPTURE, DEATH); (INSUFFICIENT INFORMATION; CAUSE IS UNKNOWN). CONCLUSIONS: KNOWN INHERENT RISK OF A PROCEDURE (MIGRATION, ENDOLEAK, ANEURYSM RUPTURE, DEATH); (INSUFFICIENT INFORMATION; CAUSE IS UNKNOWN).
THE FOLLOWING INFORMATION WAS OBTAINED FROM A JOURNAL ARTICLE. DETAILED ANALYSIS OF A SERIES OF EXPLANTED TALENT AAA STENT-GRAFTS: BIOFUNCTIONALITY ASSESSMENT. MARK NUTLEY, ROBERT GUIDOIN, TIEYING YIN, YVAN DOUVILLE, ZE ZHANG, GEORGI MARINOV, DANGHENG WEI, JING LIN, BENEDIKT WEBER, LU WANG, BIN LI, GREGORY SAMISB, YAHYE MERHI, ROBERT MCGREGOR, GUY DIONNE, NATHALIE GILBERT. (JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 21(4): 299 ¿ 319; 2011). CASE R4 HISTORY AND OUTCOME: (B)(6) OLD MALE PATIENT WITH A REMOTE HISTORY OF SUCCESSFUL TREATMENT OF TUBERCULOSIS, AND COMPLETE RECOVERY FROM TWO MINOR STROKES, WAS DIAGNOSED WITH A 6.9 CM AAA. A TALENT MODULAR STENT-GRAFT WAS DEPLOYED WITHOUT COMPLICATION, AND THE PATIENT RECOVERED FULLY. THREE YEARS LATER, THE PATIENT RECEIVE A QUADRUPLE CORONARY BYPASS. AT THIS TIME, A THORACO-ABDOMINAL CTA DEMONSTRATED THAT THE DIAMETER OF THE ABDOMINAL ANEURYSM HAD INCREASED TO 7.7 CM AND AN ASYMPTOMATIC TYPE IB ENDOLEAK OF THE LEFT LIMB WAS NOTED; IT WAS OBSERVED FLOATING FREELY IN THE COMMON ILIAC ARTERY ANEURYSM SAC. THE PATIENT WAS DISCHARGED TO A CARDIAC REHABILITATION CENTER POST CORONARY BYPASS GRAFTING (CABG) WITH THE PLAN TO CORRECT THIS ENDOLEAK ON A SEMI-URGENT BASIS. THREE WEEKS AFTER THE GABC, THE PATIENT WAS ADMITTED IN SEVERE SHOCK CAUSED BY RUPTURE OF THE PRESSURIZED AAA SAC. THE TREATING SURGEON ELECTED TO EXPLANT THE ENTIRE STENT-GRAFT, AND AN EMERGENCY OPEN AORTO-BIILIAC RECONSTRUCTION WAS PERFORMED. THE PATIENT DIED FROM MEDICAL COMPLICATIONS FROM THE PROCEDURE 3 DAYS POSTOPERATIVELY. TOTAL DURATION OF STENT GRAFT IMPLANTATION WAS 36 MONTHS. OBSERVATION OF THE EXPLANTED STENT-GRAFT: THE DEVICE EXPLANTED FROM CASE R4 APPEARS TO HAVE ULTIMATELY RESULTED FROM A TYPE 1B ENDOLEAK AT THE DISTAL LEFT LIMB. HOWEVER, POST-EXPLANTATION ANALYSIS ALSO REVEALED A NUMBER OF STRUCTURAL DEVICE FAILURES WHICH MAY HAVE CONTRIBUTED TO THIS PATIENT¿S DEATH. FIRSTLY, THERE WAS CLEAR EVIDENCE OF RUPTURE OF THE THIN PROXIMAL EXTERNAL SUPPORT WIRE AT THE DOCKING ZONE. THE EXTREMITY OF THIS WIRE WAS NO LONGER ANCHORED TO THE FABRIC. ALSO, SIGNIFICANT HOLES MEASURING MORE THAN 4 MM2 WERE OBSERVED IN THE FABRIC AT THE LEVEL OF THE BIFURCATION BETWEEN THE MAIN BODY AND THE IPSILATERAL LIMB MIDWAY BETWEEN TWO ADJACENT Z-STENTS. THESE APEXES APPEARED TO HAVE COME IN CONTACT WITH EACH OTHER DURING EACH REPETITIVE CARDIAC PULSE, CAUSING GRADUAL DESTRUCTION TO THE FABRIC AND PRESSURIZATION OF THE AAA SAC, LEADING TO DISRUPTION OF THE DISTAL SEAL ZONE. THE PHYSIOLOGICAL SIGNIFICANCE OF THIS FABRIC DEFECT WAS CONFIRMED BY EX VIVO CPS USING A COLORED GLYCEROL SOLUTION. THERE WAS MINIMAL EXTERNAL ENCAPSULATION THE GRAFT, AND THE EXTERNAL SURFACE WAS IRREGULARLY COATED WITH SCATTERED FRESH THROMBI.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 673965 | TALENT | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC CARDIOVASCULAR |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00081 YR | Death| R |