TEBBETTS FIBEROPTC SS RETR 9CMX24MM BLDE
Report
- Report Number
- 1038548-2013-00031
- Event Type
- Injury
- Date Received
- November 22, 2013
- Date of Event
- October 30, 2013
- Report Date
- October 30, 2013
- Manufacturer
- CAREFUSION
- Product Code
- FDG
- PMA / PMN Number
- EXEMPT
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- NURSE
Narratives
(B)(4) - THE DEVICE WAS NOT RECEIVED FOR EVALUATION. IF THE DEVICE BECOMES AVAILABLE, A FOLLOW-UP MDR WILL BE SUBMITTED.
(B)(4) THIS COMPLAINT IS ASSOCIATED WITH (B)(4). IT WAS REPORTED THAT THE INSTRUMENT WAS GETTING HOT AND CAUSING BURNS WHERE THE CORD MEETS THE INSTRUMENT AND WHERE THE CORD HAS SUCTION. ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER ON (B)(6) 2013. IT WAS REPORTED THAT THE RETRACTOR WAS PLACED ON THE PATIENT¿S ABDOMEN AND THE PATIENT SUFFERED A BURN ON THE ABDOMEN THAT WAS TENDED TO WITH OINTMENT (TYPE UNKNOWN). THE TYPE OF PROCEDURE WAS UNKNOWN BUT WAS COMPLETED AS PLANNED. PER THE CUSTOMER, TWO TYPES OF LIGHT SOURCES WERE USED BUT IT IS UNCLEAR WHICH WAS USED IN EACH CASE. THE LIGHT SOURCES WERE ¿BFW¿ AND ¿PILLINGS¿. ON 11/12/2013, THE CUSTOMER NOTIFIED CUSTOMER ADVOCACY THAT THE INSTRUMENTS WOULD NOT BE SENT IN FOR EVALUATION ON (B)(6) 2013, A CUSTOMER VISIT WAS CONDUCTED BY CUSTOMER ADVOCACY WHO MET WITH THE FACILITIES OPERATING ROOM (OR) COORDINATOR AND THE NURSE MANAGER. THE OR COORDINATOR PROVIDED THE DEVICE 88-1088 THAT HE STATED WAS USED IN BOTH COMPLAINTS LISTED. THEREFORE A (B)(4) WILL REFLECT THE CHANGE IN THE SUBMISSION. PRIOR TO THIS VISIT, THE CUSTOMER HAD STATED THAT THE CORD USED WAS A 3.5MM WHEN IN FACT, IT WAS A 5MM CORD WHICH IS THE INCORRECT SIZE TO USE FOR THIS PRODUCT. THE LIGHT SOURCE WAS NOT BROUGHT FOR EVALUATION. THE DEVICE 88-1088 HAD A LOT CODE OF A980521 WHICH WAS CONFIRMED BY OUR MANUFACTURING FACILITY TO HAVE BEEN MANUFACTURED IN 1998. THE DEVICE POTENTIALLY HAS BEEN IN USE FOR 15 YEARS. THE CUSTOMER STATED THAT THE RETRACTOR HAD BEEN TAKEN OUT OF CIRCULATION FOR USE IN THE OPERATING ROOM. HE DID REMARK THAT THE STAFF IS AWARE OF THE ISSUE AND DO TRY TO WRAP THE INSTRUMENT IN A WET LAP AND / OR TURN OFF THE LIGHT SOURCE WHEN NOT IN USE.
BURN THE INSTRUMENT IS GETTING VERY HOT AND CAUSING BURNS WHERE THE CORD MEETS THE INSTRUMENT AND WHERE INSTRUMENT HAS SUCTION: ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER (B)(6) 2013. IT WAS REPORTED THAT THE RETRACTOR WAS PLACED ON THE PATIENT AND THE PATIENT SUFFERED A SMALL BURN ON THE CHEST AREA. PROCEDURE IS UNKNOWN BUT WAS COMPLETED AS PLANNED. OINTMENT (UNKNOWN NAME) WAS APPLIED TO THE BURN AREA. PER THE CUSTOMER, TWO TYPES OF LIGHT SOURCES WERE USED BUT IT IS UNCLEAR WHICH WAS USED IN EACH CASE. THE LIGHT SOURCES WERE "BFW" AND "PILLINGS". THE CUSTOMER HAD NO FURTHER INFORMATION ON THE LIGHT SOURCES. THIS COMPLAINT IS IN ASSOCIATION WITH (B)(4): ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER (B)(6) 2013. IT WAS REPORTED THAT WE WILL NOT BE RECEIVING THE INSTRUMENTS FOR EVALUATION AS THEY ARE STILL IN USE. THE CUSTOMER STATED THAT THEY HAD USED A 3.5 MM LIGHT CABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 608590 | TEBBETTS FIBEROPTC SS RETR 9CMX24MM BLDE | RETRACTOR, FIBEROPTIC | FDG | CAREFUSION | 88-1087 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |