FDA Adverse Event Malfunction Summary report: N

ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT

MDR report key: 3480026 · Received November 20, 2013

Report

Report Number
9611451-2013-00923
Event Type
Malfunction
Date Received
November 20, 2013
Date of Event
October 24, 2013
Report Date
October 25, 2013
Manufacturer
FISHER & PAYKEL HEALTHCARE LIMITED
Product Code
BZE
PMA / PMN Number
K983112
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
KS
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). THE COMPLAINT RT340 ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT IS EN ROUTE TO FISHER & PAYKEL HEALTHCARE IN (B)(4) FOR INVESTIGATION. WE WILL PROVIDE A FOLLOW-UP REPORT ONCE WE HAVE COMPLETED OUR INVESTIGATION.

Additional Manufacturer Narrative · 1

(B)(4). METHOD: ONLY THE INSPIRATORY LIMB OF THE COMPLAINT RT340 ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT WAS RETURNED TO FISHER & PAYKEL HEALTHCARE IN (B)(4) FOR INSPECTION. IT WAS VISUALLY INSPECTED AND ELECTRICAL RESISTANCE TESTED USING A CALIBRATED MULTIMETER. RESULTS: NO PHYSICAL DAMAGE WAS OBSERVED TO THE RETURNED INSPIRATORY TUBE. THE ELECTRICAL RESISTANCE OF THE HEATERWIRE WAS HIGHER THAN SPECIFICATION. A LOT CHECK REVEALED NO OTHER COMPLAINTS OF THIS NATURE FOR LOT NUMBER 130617. CONCLUSION: HIGH ELECTRICAL RESISTANCE IN HEATERWIRES CAN BE ASSOCIATED WITH INSUFFICIENT CONNECTION OF THE HEATERWIRE AND THE HEATERWIRE PINS DURING PRODUCTION, SUCH THAT IT IS UNABLE TO PROVIDE CONTINUITY DURING THE PERIOD OF USE. ALL RT340 ADULT BREATHING CIRCUITS ARE RESISTANCE AND CONTINUITY TESTED DURING PRODUCTION, AND THOSE THAT FAIL ARE REJECTED. THIS SUGGESTS THAT THE SUBJECT INSPIRATORY HEATERWIRE MALFUNCTIONED AFTER RELEASED FOR DISTRIBUTION. OUR MONITORING AND TRENDING OF HIGH ELECTRICAL RESISTANCE IN ADULT BREATHING CIRCUITS HAS A RATE OF OCCURRENCE OF (B)(4) DEVICES PER MILLION SOLD WORLDWIDE IN THE LAST YEAR TO THE END OF NOVEMBER 2013.

Description of Event or Problem · 1

A HOSPITAL IN (B)(6) REPORTED TO A DISTRIBUTOR THAT THE HEATERWIRE OF AN RT340 ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT WAS NOT WARMING UP. THIS WAS OBSERVED BEFORE USE ON A PATIENT.

Description of Event or Problem · 1

A HOSPITAL IN (B)(6) REPORTED TO A DISTRIBUTOR THAT THE HEATERWIRE OF AN RT340 ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT WAS NOT WARMING UP. THIS WAS OBSERVED BEFORE USE ON A PATIENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
602678 ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT BZE BZE FISHER & PAYKEL HEALTHCARE LIMITED RT340 130617

Patients

Seq Age Sex Outcome Treatment
1