CIRCUIT NEO 4FT HTD W/12IN REMOTE 30/CS
Report
- Report Number
- 8030673-2013-00055
- Date Received
- October 14, 2013
- Date of Event
- September 15, 2013
- Report Date
- September 17, 2013
- Manufacturer
- CAREFUSION
- Product Code
- BZE
- PMA / PMN Number
- K915226
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- RESPIRATORY THERAPIST
Narratives
(B)(4). DEVICE IS IN THE PROCESS OF BEING SENT TO THE MANUFACTURING PLANT. UPON CAREFUSION'S INVESTIGATION, A FOLLOW UP MEDWATCH WOULD BE SUBMITTED.
(B)(4). EVALUATION SUMMARY:THE CUSTOMER RETURNED THIRTY-FIVE (35) UNITS FOR EVALUATION. (B)(4). AT THIS TIME, THERE IS NOT ANY EVIDENCE THAT CONFIRMS THAT OUR OPERATIVE PERSONNEL ARE CONTRIBUTING TO THIS FAILURE. DURING THE MANUFACTURING REVIEW, IT WAS OBSERVED THAT THIS PRODUCT IS 100% TESTED BY RESISTANCE FUNCTION AND NO ISSUES WERE OBSERVED. IN ADDITION, NO ASSEMBLY ERRORS WERE OBSERVED DURING CURRENT PRODUCTION PROCESS. NO LOT NUMBERS WERE AVAILABLE FOR THE 4 CIRCUITS REPORTED. HOWEVER, LOT NUMBERS 0000453627 AND 0000548191 WERE OBSERVED FROM RETURNED SAMPLES. THE DEVICE HISTORY RECORD OF THESE LOTS WAS REVIEWED AND NO ISSUES WERE OBSERVED RELATED TO THIS CUSTOMER REPORT. BASED ON THE SAMPLE EVALUATION, CAREFUSION CONCLUDED THAT THE ALARMING CONDITION EXPERIENCED WITH THE CIRCUITS WAS CAUSED DUE TO THE CRACKS ON THE TEMP PROBE COMPONENT MATERIAL. IN ADDITION, THE ALARMING CONDITION EXPERIENCED COULD BE CAUSED DUE TO THE NO READING ON THE WIRE OF THE CIRCUIT. AS A CORRECTIVE ACTION, FOR THE CRACK CONDITION ON THE TEMP PROBE, A NEW MATERIAL WAS QUALIFIED (POLYCARBONATE) TO REDUCE THE RISK OF CRACKS ON THESE COMPONENTS. FOR THE PROBLEM FOUND IN THE WIRE OF THE CIRCUIT (NO RESISTANCE OUT OF RANGE AND/OR READING) AN IMPROVEMENT IS BEING QUALIFIED AND VALIDATED. A NEW CLAMP IS BEING QUALIFIED IN ORDER TO HAVE A BETTER/PROPER ASSEMBLY BETWEEN CLAMP AND WIRE AND REDUCE FAILURE ON RESISTANCE.
CUSTOMER REPORTED: WE HAVE HAD 4 CIRCUITS THAT PASSED THE PRETEST, BUT WHEN PUT ON THE (B)(6), THE HEATER WOULD NOT HEAT (WOULD NOT GO ABOVE 23C- MR820 HEATER), THE LOW PRESSURE ALARM ALARMED AND THE FLOW SENSOR ALARMED ¿O2 MEASUREMENT OUT OF RANGE¿. THERE WAS NO PATIENT HARM AS THE PATIENTS WERE MANUALLY VENTILATED WHILE THE CIRCUITS WERE IMMEDIATELY SWITCHED TO EVAQUA CIRCUITS WITH NO FURTHER ISSUES. THE LOT NUMBERS WERE NOT KNOWN SINCE THE LABEL WAS DISCARDED, BUT CUSTOMER STATED SHE HAS LOT NUMBERS: 0000453627 AND 0000548191. THE DRAGER VENT WAS USED WITH ALL THESE CIRCUITS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 526020 | CIRCUIT NEO 4FT HTD W/12IN REMOTE 30/CS | HEATER, BREATHING SYSTEM W/WO CONTROLLER (NOT HUMIDIFIER OR NEBULIZER | BZE | CAREFUSION | RT4851-12 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |