FDA Adverse Event Injury Summary report: N

MAXENON XI 300-WATT XENON LIGHT SOURCE

MDR report key: 3370097 · Received September 16, 2013

Report

Report Number
3005775121-2013-00003
Event Type
Injury
Date Received
September 16, 2013
Date of Event
August 15, 2013
Report Date
September 10, 2013
Manufacturer
QED, INC
Product Code
GCT
PMA / PMN Number
NA
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

BFW, INC (RELABELER OF THIS DEVICE) RECEIVED A CALL FROM THE FACILITY ON (B)(6) 2013 REPORTING THAT DURING A SURGICAL PROCEDURE USING THE MAXENON XI 300-WATT XENON LIGHT SOURCE AND HIGH BEAM FIBER OPTIC HEADLIGHT A PT WAS BURNED. ACCORDING TO THE FACILITY, THE EVENT OCCURRED (B)(6) 2013. THE FACILITY INFORMED BFW THAT THE MAXENON XI HAD BEEN SENT TO A NON-BFW REPAIR FACILITY ON (B)(4) 2013, PHYSICIANS BIOMED, TO HAVE THE 300-WATT XENON LAMP REPLACED. THE XENON LAMP FOR THE MAXENON XI REQUIRES A COOLING RING/HEAT SHIELD COMPONENT BE REMOVED FROM THE OLD LAMP AND INSTALLED ON THE NEW LAMP PRIOR TO INSERTING THE LAMP INTO THE HOUSING AND BACK INTO THE LIGHT SOURCE OR EXCESSIVE TEMPERATURES WILL OCCUR. THIS IS NOTED SEVERAL TIMES IN THE OPERATION MANUAL. IT IS ALSO STATED IN THE MANUAL THAT LAMPS NOT PURCHASED AND INSTALLED BY BFW WILL NOT BE WARRANTED. UPON RECEIPT OF THE MAXENON XI LIGHT SOURCE FROM THE FACILITY IT WAS FOUND THAT THE LAMP WAS PLACED INTO THE LIGHT SOURCE WITHOUT THE COOLING RING/HEAT SHIELD. THE HIGH BEAM HEADLIGHTS AND FIBER OPTIC CABLES RECEIVED AT BFW FROM THE FACILITY WERE IMPACTED BY THE EXCESSIVE HEAT AS WELL. THE MAXENON XI WAS SOLD TO THE FACILITY IN (B)(4) OF 2006. THIS FACILITY HAS NOT PURCHASED XENON LAMPS FROM BFW. THE FACILITY SENT IN MAXENON XI LIGHT SOURCE, TWO HIGH BEAM HEADLIGHTS WITH FIBER OPTIC CABLES. UPON RECEIPT, THE LAMP WAS CHECKED AND FOUND TO BE INSTALLED WITHOUT THE COOLING RING/HEAT SHIELD. EQUIPMENT WAS SENT TO THE ORIGINAL MFR (QED, INC) WHO CONFIRMED THE SAME. WITH A REPLACEMENT LAMP THAT INCLUDES THE COOLING RING/HEAT SHIELD THE UNIT WILL OPERATE SAFELY WAS DESIGNED.

Description of Event or Problem · 1

ON (B)(6) 2013, BFW RECEIVED A CALL FROM CRANE CREEK SURGERY CENTER REGARDING A PROCEDURE INVOLVING THE MAXENON XI-300WATT XENON LIGHT SOURCE AND HIGH BEAM FIBER OPTIC HEADLIGHT THAT RESULTED IN A BURN TO A PT. THE EVENT OCCURRED (B)(6) 2013, HOWEVER, BFW ONLY BECAME AWARE OF THE EVENT (B)(4) 2013.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
465034 MAXENON XI 300-WATT XENON LIGHT SOURCE MAXENON XI GCT QED, INC MID 3010 NA

Patients

Seq Age Sex Outcome Treatment
1 NA