TAXUS? ELEMENT?
Report
- Report Number
- 2134265-2013-06325
- Event Type
- Death
- Date Received
- September 18, 2013
- Date of Event
- September 30, 2012
- Report Date
- August 20, 2013
- Manufacturer
- BOSTON SCIENTIFIC - GALWAY
- Product Code
- NIQ
- PMA / PMN Number
- P100023
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- PHYSICIAN
Narratives
DEVICE EVALUATED BY MFR: THE DEVICE HAS NOT BEEN RECEIVED FOR ANALYSIS; THEREFORE A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. THE MANUFACTURING BATCH RECORD REVIEW CONFIRMED THAT THE DEVICE MET ALL MATERIAL, ASSEMBLY AND PERFORMANCE SPECIFICATIONS. THE ROOT CAUSE IS ANTICIPATED PROCEDURAL COMPLICATIONS AS THIS EVENT IS A KNOWN PHYSIOLOGICAL EFFECT OF THE PROCEDURE AND IS NOTED WITHIN THE DFU. (B)(4).
SAME CASE AS MDR ID# 2134265-2013-06326; SAME CASE AS MDR ID# 2134265-2013-06328; SAME CASE AS MDR ID# 2134265-2013-06329; SAME CASE AS MDR ID# 2134265-2013-06373. (B)(4). IT WAS REPORTED THAT POST A PERCUTANEOUS CORONARY INTERVENTION PROCEDURE, THE PATIENT EXPERIENCED A MYOCARDIAL INFARCTION AND EXPIRED. (B)(6) 2011 THE PATIENT PRESENTED DUE TO STABLE ANGINA. THE PHYSICIAN TREATED THREE DIFFERENT LESIONS. LESION 1 WAS A LONG LESION LOCATED IN THE PROXIMAL LEFT ANTERIOR DESCENDING (LAD) ARTERY TO DISTAL LAD WITH 75% STENOSIS AND WAS 65 MM LONG WITH A REFERENCE VESSEL DIAMETER OF 2.75 MM. THE PHYSICIAN TREATED THE LESION WITH PRE-DILATATION AND IMPLANTATION OF OVERLAPPING 2.5 X 24 MM, 2.5 X 32 MM , AND 3.0 X 16 MM TAXUS ELEMENT STENTS. FOLLOWING POST-DILATATION, RESIDUAL STENOSIS WAS 0%. LESION 2 WAS LOCATED IN THE 1ST DIAGONAL WITH 75% STENOSIS AND WAS 12 MM LONG WITH A REFERENCE VESSEL DIAMETER OF 2.4 MM. THE PHYSICIAN TREATED THE LESION WITH DIRECT STENT PLACEMENT USING A 2.5 X 16 MM TAXUS ELEMENT STENT WITH 0% RESIDUAL STENOSIS. LESION 3 WAS LOCATED IN THE 2ND OBTUSE MARGINAL WITH 75% STENOSIS AND WAS 15 MM LONG WITH A REFERENCE VESSEL DIAMETER OF 2.8 MM. THE PHYSICIAN TREATED THE LESION WITH DIRECT STENT PLACEMENT OF A 3.0 X 20 MM TAXUS ELEMENT STENT WITH 0% RESIDUAL STENOSIS. POST INDEX PROCEDURE, THE PATIENT HAD ELEVATED TROPONIN VALUES (PEAK TROPONIN= 137 NG/L, UL= 14 NG/L). NO ISCHEMIC SYMPTOMS WERE OBSERVED AND NO ACTION WAS TAKEN TO TREAT THIS EVENT. THE PATIENT WAS DISCHARGED 2 DAYS LATER ON ASPIRIN AND CLOPIDOGREL. (B)(6) 2013, 438 DAYS POST INDEX PROCEDURE THE PATIENT EXPERIENCED AN MYOCARDIAL INFARCTION AND SUBSEQUENTLY EXPIRED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 469982 | TAXUS? ELEMENT? | CORONARY DRUG-ELUTING STENT | NIQ | BOSTON SCIENTIFIC - GALWAY | H7493902524250 | 13603203 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 55 YR | Death |