FDA Adverse Event Malfunction Summary report: N

ACS HI-TORQUE CROSS-IT GUIDE WIRE WITH HYDROCOAT HYDROPHILIC COATING

MDR report key: 3335874 · Received September 9, 2013

Report

Report Number
2024168-2013-05746
Event Type
Malfunction
Date Received
September 9, 2013
Date of Event
March 1, 2011
Report Date
July 18, 2013
Manufacturer
AV-TEMECULA-CT
Product Code
DQX
PMA / PMN Number
K060449
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). PATIENT AGE ESTIMATED AS 50. PATIENT GENDER ESTIMATED AS MALE. DATE OF EVENT ESTIMATED AS 03/01/2011. IT IS INDICATED THAT THE DEVICE IS NOT RETURNING FOR EVALUATION; THEREFORE A FAILURE ANALYSIS OF THE COMPLAINT DEVICE COULD NOT BE COMPLETED. A REVIEW OF THE LOT HISTORY RECORD AND COMPLAINT HISTORY OF THE REPORTED LOT COULD NOT BE CONDUCTED BECAUSE THE LOT NUMBER WAS NOT PROVIDED. BASED ON THE INFORMATION REVIEWED, THERE IS NO INDICATION OF A PRODUCT DEFICIENCY. THE ADDITIONAL DEVICES REFERENCED ARE BEING FILED UNDER SEPARATE MEDWATCH REPORTS. ARTICLE; CAUSES OF FAILURE WITH SZABO TECHNIQUE - AN ANALYSIS OF NINE CASES.

Description of Event or Problem · 1

THIS EVENT WAS CAPTURED BASED ON REVIEW OF THE ARTICLE, CAUSES OF FAILURE WITH SZABO TECHNIQUE - AN ANALYSIS OF NINE CASES. IT WAS REPORTED THAT FROM MARCH 2009 TO MARCH 2011, 42 PATIENTS WITH AN OSTIAL LESION WERE TREATED PERCUTANEOUSLY USING SZABO TECHNIQUE IN A MONORAIL STENT SYSTEM. IN 57% OF PATIENTS, DRUG-ELUTING STENTS WERE USED (INCLUDING THE XIENCE V) AND IN 42.8% PATIENTS BARE METAL STENTS (INCLUDING THE ZETA). THE STENT WAS ADVANCED OVER TWO WIRES, THE TARGET WIRE AND THE ANCHOR WIRE. THE ANCHOR WIRES USED INCLUDED THE ALLSTAR GUIDE WIRES AND THE BALANCE MIDDLEWEIGHT (BMW) GUIDE WIRES. THE TARGET GUIDE WIRES USED INCLUDED THE CROSS IT GUIDE WIRE AND THE MIRACLEBROS GUIDE WIRE. THE PROCEDURE WAS CONSIDERED TO BE SUCCESSFUL IF STENT WAS PLACED PRECISELY COVERING THE LESION AND WITHOUT STENT LOSS OR ANCHOR WIRE PROLAPSING. OF THE TOTAL 42 PATIENTS, THE PROCEDURE WAS SUCCESSFUL IN 33, WHILE FAILED IN 9. FAILURES WERE DUE TO WIRE ENTANGLEMENT, STENT DISLODGMENT, FAILURE TO CROSS, AND PROLAPSE OF A NON-ABBOTT GUIDE WIRE. NO ADDITIONAL INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
450041 ACS HI-TORQUE CROSS-IT GUIDE WIRE WITH HYDROCOAT HYDROPHILIC COATING GUIDE WIRE DQX AV-TEMECULA-CT

Patients

Seq Age Sex Outcome Treatment
1 50 YR