FDA Adverse Event Injury Summary report: N

2520274-2013-05304

MDR report key: 3325067 · Received September 4, 2013

Report

Report Number
2520274-2013-05304
Event Type
Injury
Date Received
September 4, 2013
Report Date
August 8, 2013
Manufacturer
SYNTHES USA
Product Code
HSB
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

THIS DEVICE USED FOR TREATMENT AND NOT DIAGNOSIS. PT'S AGE: MEAN AGE: 78.1 YEARS PT'S SEX: 74.2% WOMAN: 25.8% MEN. DATE OF EVENT: 2003. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. PLACEHOLDER.

Additional Manufacturer Narrative · 1

ADDITIONAL NARRATIVE: THIS DEVICE USED FOR TREATMENT AND NOT DIAGNOSIS. FROM FFN TO PFN.

Description of Event or Problem · 1

JOURNAL ARTICLE RECEIVED: INTRAMEDULLARY FIXATION OF INTERTROCHANTERIC FRACTURES WITH THE PROXIMAL FEMORAL NAIL (PFN). ORTHOP TRAUMATOL, 2003: 15: 20-37.: AUTHORS: AKHIL P. VERHEYDEN AND CHRISTOPH JOSTEN. THIS STUDY WAS DONE BETWEEN JANUARY 1, 1996 AND MARCH 31, 1999 WITH 231 PATIENTS IMPLANTED WITH THE FFN SYSTEM. THE STUDY SHOWS THE TECHNIQUE USED, INTRA- OPERATIVE AND POST-OPERATIVE COMPLICATIONS, AND LATE COMPLICATIONS. INTRA-OPERATIVE COMPLICATIONS: THREE INADEQUATE REDUCTIONS RESULTING IN A REVISION: ONE ANTIROTATION SCREW WAS INSERTED TOO DEEP REQUIRING REMOVAL THROUGH THE FRACTURE GAP. POST-OPERATIVE COMPLICATIONS REPORTED: TWELVE PATIENTS DIED WHILE IN THE HOSPITAL: ONE FEMORAL FRACTURE; OSTEOPOROTIC BEDRIDDEN PATIENT FELL OUT OF BED: THREE PATIENTS THE IMPLANT BROKE; CAUSE IN ALL 3 WAS INADEQUATE REDUCTION AND SUBOPTIMAL PLACEMENT OF THE NECK SCREW IN THE NECK/HEAD FRAGMENT: 14 PATIENTS DEVELOPED A HEMATOMA OR SEROMA; IF THE SONAGRAPHICALLY CONFIRMED THICKNESS OF THE FLUID COLLECTION EXCEEDED 1 CM, A REVISION WAS DONE: THREE DEEP INFECTIONS; HEALED AFTER IMPLANT REMOVAL: ONE DEEP INFECTION WITH LOOSENING REQUIRING A GIRDLESTONE PROCEDURE. LATE COMPLICATIONS REPORTED: NINE PATIENTS THE ANTIROTATION SCREW MIGRATED; 8TIMES BACKING OUT LATERALLY,1 MIGRATING MEDIALLY ONTO THE JOINT: 2 CASES OF LATE ABSCESS FORMATION. THIS COMPLAINT IS ON THE POST-OPERATIVE ONE DEEP INFECTION WITH LOOSENING REQUIRING A GIRDLESTONE PROCEDURE. (NAIL) THIS IS 1 OF 3 REPORTS FOR COMPLAINT (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
439072 HSB SYNTHES USA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention