DA VINCI SI SURGICAL SYSTEM
Report
- Report Number
- 2955842-2013-03015
- Event Type
- Other
- Date Received
- August 9, 2013
- Date of Event
- July 11, 2013
- Report Date
- July 11, 2013
- Manufacturer
- INTUITIVE SURGICAL, INC.
- Product Code
- NAY
- PMA / PMN Number
- K081137
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FL, US
- Reporter Occupation
- NURSE
Narratives
THE INVESTIGATION PERFORMED BY INTUITIVE SURGICAL, INC (ISI) FIELD SERVICE ENGINEERING WAS UNABLE TO REPLICATE THE ISSUE EXPERIENCED BY THE SURGEON. THIS COMPLAINT IS BEING REPORTED DUE TO THE FOLLOWING CONCLUSION: THE SURGEON MADE THE DECISION TO CONVERT TO OPEN SURGICAL TECHNIQUES AFTER EXPERIENCING NON-INTUITIVE MOVEMENT.
IT WAS REPORTED THAT DURING A DA VINCI SI HYSTERECTOMY PROCEDURE, THE SURGEON EXPERIENCED NON-INTUITIVE MOTION WHILE MANIPULATING THE INSTRUMENTS INSTALLED ON THE PT SIDE MANIPULATOR (PSM) ARMS FROM THE MASTER TOOL MANIPULATORS. IT WAS ALSO REPORTED THAT THE SURGEON EXPERIENCED DIFFICULTY USING CAUTERY. THE SITE CONTACTED INTUITIVE SURGICAL, INC (ISI) FOR TROUBLESHOOTING ASSISTANCE, AFTER THE SURGEON HAD MADE THE DECISION TO COMPLETE THE SURGICAL PROCEDURE USING OPEN SURGICAL TECHNIQUES. NO PT HARM WAS REPORTED. REVIEW OF THE SITE'S SYSTEM LOGS BY THE TSE FOUND THAT THERE WERE NO SYSTEM ERRORS CODES GENERATED RELATED TO THE REPORTED ISSUE. ON (B)(4) 2013 ISI CONTACTED THE NURSE MANAGER WHO INITIALLY REPORTED THIS COMPLAINT. THE NURSE MANAGER INDICATED THAT SHE WAS PRESENT DURING THE SURGICAL PROCEDURE. THE PT WAS PLACED IN THE TRENDELENBURG POSITION AND THAT SHE OBSERVED THAT THE PORT SITE INCISIONS WERE SLIGHTLY CLOSE AND THE PSMS WERE "TOO STRAIGHT". SHE INDICATED THAT THE SURGICAL STAFF ATTEMPTED TO TROUBLESHOOT THE ISSUE, BUT WERE UNABLE TO RESOLVE THE ISSUE. THE NURSE MANAGER WAS UNABLE TO PROVIDE THE DETAILS CONCERNING THE SPECIFIC TROUBLESHOOTING TECHNIQUES THAT WERE PERFORMED TO RESOLVE THE ISSUE. ON (B)(4) 2013 ISI CONTACTED THE SURGEON WHO PERFORMED THE SURGICAL PROCEDURE. THE SURGEON INDICATED THAT APPROX 20 MINUTES INTO THE DA VINCI SURGICAL PROCEDURE, HE OBSERVED THAT THE IMAGE THROUGH THE HIGH RESOLUTION STEREO VIEWER (HRSV) WAS INVERTED. AFTER ACTIVATING CAUTERY ENERGY WHILE USING THE RIGHT MASTER TOOL MANIPULATOR, TISSUE ON THE LEFT SIDE WAS CAUTERIZED. THERE WAS NO INJURY TO THE PT, AS THE AFFECTED TISSUE WAS BEING CAUTERIZED AS PART OF THE SURGICAL PROCEDURE. THE SURGEON INDICATED THAT THERE WERE NO ISSUES WITH PLACEMENT OF THE PORT SITE INCISION OR THE PORTION OF THE PSM DURING THE SURGICAL PROCEDURE. HE INDICATED THAT THE SURGEON SIDE CONSOLE SETTINGS WERE FOUND TO BE CORRECT AND THERE WERE NO CAMERA ISSUES THAT OCCURRED DURING THE SURGICAL PROCEDURE. THE SURGEON INDICATED THAT THE PT TOLERATED THE OPEN PROCEDURE WELL AND IS RECOVERING WELL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 381598 | DA VINCI SI SURGICAL SYSTEM | ENDOSCOPIC INSTRUMENT CONTROL SYSTEM, NAY | NAY | INTUITIVE SURGICAL, INC. | IS3000 A6.0P6 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 51 YR | Other | ESU| ACCESSORY| DAV SI SURG. SYSTEM INSTRUMENTS |