PELVILACE BIOURETHRAL SUPPORT SYSTEM
Report
- Report Number
- 1018233-2013-02832
- Event Type
- Injury
- Date Received
- July 12, 2013
- Report Date
- June 13, 2013
- Manufacturer
- TISSUE SCIENCE LABORATORIES
- Product Code
- FTL
- PMA / PMN Number
- K031295
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- ATTORNEY
Narratives
THE SAMPLE WAS NOT RETURNED. THE FINISHED PRODUCT MET ALL SPECIFICATIONS PRIOR TO BEING RELEASED FOR GENERAL DISTRIBUTION. THE INSTRUCTIONS FOR USE WHICH ACCOMPANIES ALL DEVICES CURRENTLY ADDRESSES POTENTIAL RISKS ASSOCIATED WITH SURGICALLY IMPLANTED MATERIALS. THE INSTRUCTIONS FOR USE STATES IN THE PRECAUTIONS: "THE PELVILACE BIOURETHRAL SUPPORT SYSTEM IS FOR SINGLE PATIENT USE ONLY AND IS TO BE IMPLANTED SURGICALLY. DO NOT USE THE PELVILACE BIOURETHRAL SUPPORT SYSTEM IF THE INTEGRITY OF THE PACKAGING APPEARS COMPROMISED. THE PELVILACE BIOURETHRAL SUPPORT SYSTEM PELVICOL IMPLANT SHOULD BE HYDRATED OR MOIST WHEN THE PACKAGE IS OPENED. DEHYDRATED OR DRY TISSUE SHOULD NOT BE IMPLANTED. POSTOPERATIVE RETROPUBIC BLEEDING MAY OCCUR IN SOME PATIENTS AND MUST BE CONTROLLED PRIOR TO PATIENT RELEASE. THE PELVILACE BIOURETHRAL SUPPORT SYSTEM PROCEDURE REQUIRES DILIGENT ATTENTION TO ANATOMICAL STRUCTURE AND CARE TO AVOID PUNCTURE OF LARGE VESSELS, NERVES, BLADDER, AND BOWEL, DURING NEEDLE PASSAGE. PROPER PLACEMENT OF THE PELVILACE BIOURETHRAL SUPPORT SYSTEM AT MID-URETHRA REQUIRES THAT THE TISSUE LIE FLAT WITH MINIMAL OR NO TENSION UNDER THE URETHRA. THE PELVILACE BIOURETHRAL SUPPORT SYSTEM IS INTENDED AS A SINGLE USE, DISPOSABLE DEVICE. DO NOT RESTERILIZE ANY PORTION OF THE PELVILACE BIOURETHRAL SUPPORT SYSTEM. PATIENTS SHOULD BE ADVISED THAT PREGNANCY FOLLOWING A PELVILACE BIOURETHRAL SUPPORT SYSTEM PROCEDURE MAY NEGATIVELY AFFECT THE SUCCESS OF THE PREVIOUS PROCEDURE AND INCONTINENCE MAY REOCCUR. THE SAFETY AND EFFECTIVENESS OF PELVILACE BIOURETHRAL SUPPORT SYSTEM HAS NOT BEEN ESTABLISHED FOR THE TREATMENT OF STRESS URINARY INCONTINENCE IN MALES AND CHILDREN UNDER THE AGE OF 18." (B)(4).
COMPLAINT #(B)(4). THE PATIENT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. PER ADDITIONAL INFORMATION RECEIVED, THE PATIENT HAS EXPERIENCED A HEMOGLOBIN DROP FROM 9.9 TO 6.5 REQUIRING BLOOD TRANSFUSION, JP DRAIN OUTPUT "240," ACUTE ANEMIA, "POSTOP BLEED WITH TAKE-BACK FOR LAPAROTOMY," AND "ACUTE BLOOD LOSS ANEMIA-STABLE AFTER 2 UNITS PACKED RED BLOOD CELLS".
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 324166 | PELVILACE BIOURETHRAL SUPPORT SYSTEM | FTL | TISSUE SCIENCE LABORATORIES | NA | BMWE0014 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 41 YR | Required Intervention |