CARPENTIER-EDWARDS PERIMOUNT THEON PERICARDIAL BIOPROSTHESIS
Report
- Report Number
- 2015691-2013-20581
- Event Type
- Injury
- Date Received
- July 12, 2013
- Date of Event
- May 30, 2013
- Report Date
- June 12, 2013
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- PMA / PMN Number
- P860057/S022
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KY, US
- Reporter Occupation
- OTHER
Narratives
(B)(4): VEGETATIONS. ENDOCARDITIS IS AN INFLAMMATION OF THE INSIDE LINING OF THE HEART CHAMBERS AND HEART VALVES. ENDOCARDITIS IS USUALLY THE RESULT OF A BLOOD INFECTION AS BACTERIA OR OTHER INFECTIOUS SUBSTANCES ENTER THE BLOODSTREAM AND TRAVEL TO THE HEART, WHERE THEY CAN SETTLE ON HEART VALVES. ENDOCARDITIS CAN POTENTIALLY LEAD TO DISORDERS SUCH AS SEVERE VALVULAR INSUFFICIENCY AND REGURGITATION. PATIENT RISK FACTORS FOR DEVELOPING ENDOCARDITIS INCLUDE INTRAVENOUS DRUG USE, CENTRAL VENOUS ACCESS LINES, PRIOR VALVE SURGERY, RECENT DENTAL SURGERY, RHEUMATIC FEVER, AND WEAKENED VALVES. EXISTING HEART DISEASE AND ABNORMALITIES INCREASE THE LIKELIHOOD OF DEVELOPING ENDOCARDITIS. IN THIS CASE, THE PATIENT'S MEDICAL RECORDS DOCUMENT A HISTORY OF (B)(6) REQUIRING MITRAL VALVE REPLACEMENT. EDWARDS LIFESCIENCES PRODUCES AND PROVIDES STERILE TISSUE BIOPROSTHESES TO ITS CUSTOMERS BY FOLLOWING CAREFULLY DESIGNED ROBUST STERILIZATION PROCESSES. THESE MANUFACTURING PROCESSES HAVE BEEN VALIDATED AND DEMONSTRATED TO CONSISTENTLY PROVIDE A SIGNIFICANT SAFETY FACTOR FROM WHICH MICROORGANISMS COULD NOT SURVIVE. MICROBIOLOGY AND PROCESS MONITORING IS ROUTINELY REVIEWED WITHIN QUALITY SYSTEMS TO MAINTAIN STERILITY CONTROL. VALIDATED TESTING HAS DEMONSTRATED THAT MICROORGANISMS COULD NOT SURVIVE EDWARDS¿ MULTI-STAGE PROCESSING WITH ENHANCED STERILANT OR HEATED GLUTARALDEHYDE TERMINAL STERILANT SOLUTION. THESE MULTIPLE, REDUNDANT MANUFACTURING CONTROLS ENSURE THE STERILITY OF EDWARDS¿ VALVES AS PROVIDED TO CUSTOMERS. THEREFORE THE PROBABILITY OF ENDOCARDITIS RELATED TO EDWARDS¿ BIOPROSTHESES IS REMOTE. IT APPEARS THAT THE PATIENT'S ENDOCARDITIS MAY HAVE BEEN RELATED TO HER PREVIOUS CASE OF ENDOCARDITIS. HOWEVER, THE ROOT CAUSE OF THIS EVENT CANNOT BE CONCLUSIVELY DETERMINED WITHOUT THE SAMPLE DEVICE. NO FURTHER ACTIONS ARE POSSIBLE WITH THE AVAILABLE INFORMATION.
IT WAS REPORTED THAT THE VALVE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 5 YEARS DUE TO ENDOCARDITIS. PER THE PATIENT'S PRE-OP WORKUP, SHE HAS A HISTORY OF (B)(6) REQUIRING MITRAL VALVE REPLACEMENT (MVR) IN 2008 (IMPLANTATION OF SUBJECT DEVICE). THE PATIENT RECENTLY UNDERWENT TEE SHOWING SEVERE MITRAL REGURGITATION AND VEGETATION OF THE PROSTHETIC MITRAL VALVE. THE PATIENT UNDERWENT REDO-MVR WITH ANOTHER EDWARDS BIOPROSTHETIC VALVE ON (B)(6) 2013.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 323607 | CARPENTIER-EDWARDS PERIMOUNT THEON PERICARDIAL BIOPROSTHESIS | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES | 6900PTFX |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 41 YR | Hospitalization| L| R |