FDA Adverse Event Injury Summary report: N

COGNIS

MDR report key: 3212541 · Received July 9, 2013

Report

Report Number
2124215-2013-08574
Event Type
Injury
Date Received
July 9, 2013
Date of Event
April 16, 2013
Report Date
June 28, 2013
Manufacturer
GUIDANT CRM CLONMEL IRELAND
Product Code
NIK
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
VA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

AT THIS TIME THIS PRODUCT HAS NOT BEEN RETURNED TO BOSTON SCIENTIFIC FOR ANALYSIS. THIS INVESTIGATION WILL BE UPDATED SHOULD FURTHER INFORMATION BE PROVIDED.

Additional Manufacturer Narrative · 1

UPON RECEIPT AT OUR POST MARKET QUALITY ASSURANCE LABORATORY, THIS CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) WAS THOROUGHLY INSPECTED AND ANALYZED. EXTERNAL VISUAL INSPECTION OF THE DEVICE REVEALED NO ANOMALIES. REVIEW OF THE DEVICE MEMORY CONFIRMED THAT FAULT CODE 1003 WERE RECORDED ON (B)(6) 2013. ALTHOUGH THE DEVICE MEMORY DIAGNOSTICS DEMONSTRATED THAT THE DAILY BATTERY VOLTAGE MEASUREMENTS DISPLAYED AN IRREGULAR PATTERN OF DISCHARGE, THE BATTERY VOLTAGE LEVEL AT EXPLANT (2.946 VOLTS) WAS SUFFICIENT TO ENSURE THERAPY AVAILABILITY/DELIVERY WHILE THE DEVICE WAS IMPLANTED. THE DEVICE CASE WAS THEN OPENED TO FACILITATE ANALYSIS OF THE INTERNAL COMPONENTS. THE BATTERY WAS SEPARATED FROM THE OTHER DEVICE ELECTRONICS AND THE OVERALL CURRENT DRAW OF THE CIRCUITRY WAS MEASURED. A NORMAL CURRENT DRAIN WAS OBSERVED WITHIN THE CIRCUITRY. COLLECTIVELY, THE PATTERN OF IRREGULAR DAILY BATTERY VOLTAGE MEASUREMENTS IN CONJUNCTION WITH NORMAL POWER LEVELS AND DEVICE HYBRID CURRENT DRAW IS CONSISTENT WITH BEHAVIOR OF DEVICES WHERE A LATENT CURRENT LEAKAGE PATH HAS OCCURRED WITHIN THE BATTERY ITSELF, RESULTING IN A PARTIAL DEPLETION OF THE BATTERY.

Description of Event or Problem · 1

BOSTON SCIENTIFIC RECEIVED INFORMATION THAT DURING A PATIENT FOLLOW UP, TONES (REPORTED IN THE PER) WERE BEING EMITTED FROM THIS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD). WHEN THE ICD WAS INTERROGATED, THE FAULT CODE 1003 WAS DISPLAYED ALONG WITH THE MESSAGE THAT THE VOLTAGE WAS TOO LOW FOR THE PROJECTED REMAINING CAPACITY. A MEMORY DOWNLOAD WAS PERFORMED AND SENT TO BOSTON SCIENTIFIC TECHNICAL SERVICES (TS) FOR ANALYSIS. NO ADVERSE PATIENT EFFECTS WERE REPORTED. A BOSTON SCIENTIFIC ENGINEER REVIEWED THE DATA AND DISCUSSED THAT THE BATTERY IS SHOWING A HIGH CURRENT DRAIN AND SHOULD BE REPLACED AS SOON AS POSSIBLE. THE DEVICE WAS EXPLANTED AND NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

Description of Event or Problem · 1

--

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
313120 COGNIS IMPLANTABLE CHF PULSE GENERATOR NIK GUIDANT CRM CLONMEL IRELAND N119

Patients

Seq Age Sex Outcome Treatment
1 67 YR Hospitalization| L| R 4555| N119| 5076| 4549| 0185