FDA Adverse Event Injury Summary report: N

INFUSE BONE GRAFT

MDR report key: 3200869 · Received July 2, 2013

Report

Report Number
1030489-2013-02856
Event Type
Injury
Date Received
July 2, 2013
Report Date
March 1, 2018
Manufacturer
MEDTRONIC SOFAMOR DANEK USA, INC
Product Code
NEK
PMA / PMN Number
P000058
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

(B)(6). (B)(4). NEITHER THE DEVICE NOR FILMS OF APPLICABLE IMAGING STUDIES WERE RETURNED TO THE MANUFACTURER FOR EVALUATION. THEREFORE, WE ARE UNABLE TO DETERMINE THE DEFINITIVE CAUSE OF THE REPORTED EVENT. PRODUCTS FROM MULTIPLE MANUFACTURERS WERE IMPLANTED DURING THE PROCEDURE. ALTHOUGH IT IS UNKNOWN IF ANY OF THE DEVICES CONTRIBUTED TO THE REPORTED EVENT, WE ARE FILING THIS MDR FOR NOTIFICATION PURPOSES.

Additional Manufacturer Narrative · 1

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Additional Manufacturer Narrative · 1

IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT SUSTAINED UNSPECIFIED INJURIES FOLLOWING THE USE OF RHBMP-2/ACS IN AN UNSPECIFIED SPINAL FUSION SURGERY. NO ADDITIONAL INFORMATION WAS REPORTED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT UNDERWENT FUSION SURGERY IN WHICH RHBMP2/ACS WAS USED. POST-OPERATIVELY, IMAGES WERE REVIEWED ON (B)(6) 2009. FINDINGS: OBTAINED AND REVIEWED, 4+ VIEWS OF THE LUMBAR SPINE DEMONSTRATE INTERBODY GRAFT WITH ANTERIOR FIXATION AT L4-5 AND L5-S1. THE L4-5 FUSION ANTERIORLY APPEARS FAIRLY ROBUST. THERE APPEARS TO BE A RADIOLUCENT LINE, ESPECIALLY ON THE OBLIQUES AT THE L5-S1 LEVEL WHICH WE ARE ABLE TO SEE TODAY WHICH MAKES ME SUSPICIOUS FOR A PSEUDOARTHROSIS OR INCOMPLETE FUSION AT THE L5-S1 LEVEL. CT SCAN FINDINGS: WE DID REVIEW A CT SCAN TODAY AS WELL AS WHICH DEMONSTRATES CALCIFICATION IN THE SPINAL CANAL AT THE L4-5 AND THE L5-S1 LEVEL AS WELL AND POSTERIOR TO THE L5 VERTEBRA. THIS APPEARS TO BE CALCIFICATION IN BONE FORMATION LEADING FROM THE DISC SPACE OUT INTO THE POSTERIOR CANAL. THE L4-5 FUSION IS MOST LIKELY FUSED, AND I WOULD SAY THAT THE L5-S1 LEVEL IS SUSPICIOUS AND POSSIBLY NOT FUSED. THIS MATERIAL IS IN THE REGION DECOMPRESSING THE EXITING L4 NERVE ROOT AS WELL AS THE L5 TRAVERSING ROOT DOWN TOWARDS S1 ON THE RIGHT SIDE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
301599 INFUSE BONE GRAFT FILLER, RECOMBINANT HUMAN BONE MORPHOGENETIC PROTEIN, COLLAGEN SCAFFOLD WITH MET NEK MEDTRONIC SOFAMOR DANEK USA, INC NA UNK

Patients

Seq Age Sex Outcome Treatment
1 Other