AJUST ADJUSTABLE SINGLE INCISION SLING
Report
- Report Number
- 1018233-2013-02387
- Event Type
- Injury
- Date Received
- June 14, 2013
- Report Date
- March 15, 2016
- Manufacturer
- BARD SHANNON LTD
- Product Code
- FTL
- PMA / PMN Number
- K092607
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CO, US
- Reporter Occupation
- ATTORNEY
- Health Professional
- N
Narratives
THE SAMPLE WAS NOT RETURNED. THE FINISHED PRODUCT MET ALL SPECIFICATIONS PRIOR TO BEING RELEASED FOR GENERAL DISTRIBUTION. THE INSTRUCTIONS FOR USE WHICH ACCOMPANIES ALL DEVICES CURRENTLY ADDRESSES POTENTIAL RISKS ASSOCIATED WITH SURGICALLY IMPLANTED MATERIALS. THE INSTRUCTIONS FOR USE STATES IN THE ADVERSE EVENTS: "COMPLICATIONS ASSOCIATED WITH THE PROPER IMPLANTATION OF THE AJUST SLING SYSTEM MAY INCLUDE, BUT ARE NOT LIMITED TO: POSTOPERATIVE HEMATOMA, SEROMA, ABSCESS OR FISTULA FORMATION, OR SCARRING WHICH MAY OCCUR FOLLOWING THE IMPLANT PROCEDURE. URINARY RETENTION, BLADDER OUTLET OBSTRUCTION AND OTHER VOIDING DYSFUNCTIONS. THESE CONDITIONS MAY BE ASSOCIATED WITH OVERCORRECTION / TOO MUCH TENSION PLACED ON THE IMPLANT. PERFORATION OR LACERATIONS OF VESSELS, NERVES, BLADDER, BOWEL, URETHRA, OR ANY VISCERA, WHICH MAY OCCUR DURING THE IMPLANTATION PROCEDURE. IRRITATION AT THE OPERATIVE WOUND SITE WHICH MAY ELICIT FOREIGN BODY RESPONSE THAT LEADS TO WOUND DEHISCENCE, INFLAMMATION AND/OR INFECTION. EXTRUSION THROUGH VAGINAL EPITHELIUM OR EROSION INTO SURROUNDING VISCERA AND/OR MUCOSA. INFLAMMATION, SENSITIZATION, PAIN, DYSPAREUNIA, SCARIFICATION, CONTRACTION, DEVICE MIGRATION AND FAILURE OF THE PROCEDURE RESULTING IN RECURRENCE OF INCONTINENCE." (B)(4).
(B)(4). THE PT'S ATTORNEY ALLEGED A DEFICIENCY AGAINST THE DEVICE. ADDITIONAL INFO HAS BEEN REQUESTED BUT NOT YET RECEIVED. ASSOCIATED MDRS: 1018233-2013-02385, 1018233-2013-02386 AND 1018233-2013-02388.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 271692 | AJUST ADJUSTABLE SINGLE INCISION SLING | Mesh, surgical, polymeric | FTL | BARD SHANNON LTD | NA | HUUK1817 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 59 YR | Female | Required Intervention | (481047, LOT# 11B02-1)| (BRD700SI, LOT# HUVG1713)| AJUST ADJUSTABLE SINGLE INCISION SLING: | PELVISOFT ACELLULAR COLLAGEN BIOMESH X2: | (481047, LOT# 11B02-1)| PELVISOFT ACELLULAR COLLAGEN BIOMESH X2:| (BRD700SI, LOT# HUVG1713)| AJUST ADJUSTABLE SINGLE INCISION SLING: |