FDA Adverse Event Malfunction Summary report: N

FRONT CUTTER

MDR report key: 3171645 · Received June 15, 2013

Report

Report Number
8030965-2013-02795
Event Type
Malfunction
Date Received
June 15, 2013
Date of Event
February 20, 2012
Report Date
February 27, 2012
Manufacturer
SYNTHES GMBH
Product Code
HXZ
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
HK
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. THE DEVICE HISTORY RECORD REPORTS THE COMPLAINT TO BE INDETERMINATE. PER SOURCE DOCUMENT. THE EXAMINATION OF THE RAW-MATERIAL TESTING CERTIFICATE AND THE MANUFACTURING DOCUMENTS SHOWED NO DEVIATIONS REGARDING MATERIAL ANALYSIS, STRENGTH AND STRUCTURAL STABILITY. THE VALUES WERE IN COMPLIANCE WITH AO-ASIF SPECIFICATION AND WITH THE INTERNATIONAL STANDARD. WE ARE NOT AWARE OF ANY OTHER SIMILAR REPORTS RELATED TO THIS ARTICLE AND LOT NUMBER. PLACEHOLDER.

Additional Manufacturer Narrative · 1

SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. (B)(6). THE EXAMINATION OF THE RAW-MATERIAL TESTING CERTIFICATE AND THE MANUFACTURING DOCUMENTS SHOWED NO DEVIATIONS REGARDING MATERIAL ANALYSIS, STRENGTH AND STRUCTURAL STABILITY. THE VALUES WERE IN COMPLIANCE WITH AO/ASIF SPECIFICATION AND WITH THE INTERNATIONAL STANDARD. SYNTHES IS NOT AWARE OF ANY OTHER SIMILAR REPORTS RELATED TO THIS ARTICLE AND LOT NUMBER. THE SURFACES OF THE CROSS-SECTIONS ARE HOMOGENOUS; NO ANOMALIES OF MATERIALS STRUCTURE WERE FOUND. THE COMPLAINT STATISTIC OF THIS ARTICLE DOES NOT SHOW AN INCREASED BREAKAGE RATE.

Description of Event or Problem · 1

DEVICE REPORT FROM SYNTHES (B)(6) REPORTS AN EVENT IN THE (B)(6) AS FOLLOWS: DURING A PROCEDURE ON (B)(6) 2012, THE FRONT CUTTER WAS USED TO CUT A 1.1MM CERCLAGE WIRE. REPORTEDLY, THE CUTTER END WAS BROKEN AND RUST WAS FOUND AT THE CRACKED AREA. IT IS SUSPECTED THE CUTTER WAS WEAKENED DUE TO RUST DEVELOPED AROUND THE AREA. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
272858 FRONT CUTTER HXZ SYNTHES GMBH 3571701

Patients

Seq Age Sex Outcome Treatment
1