FDA Adverse Event Injury Summary report: N

THERAPY COOL PATH CATHETER, 1304-CP-7-25-L-AB (USA)

MDR report key: 3152621 · Received June 5, 2013

Report

Report Number
2030404-2013-00045
Event Type
Injury
Date Received
June 5, 2013
Date of Event
May 17, 2013
Report Date
May 17, 2013
Manufacturer
ST. JUDE MEDICAL, INC. (AF-IRVINE)
Product Code
OAD
PMA / PMN Number
P060019
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
WI, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THE RESULTS OF THE INVESTIGATION ARE INCONCLUSIVE SINCE THE DEVICE WAS NOT RETURNED FOR ANALYSIS. OUR INVESTIGATION WAS LIMITED TO THE REVIEW OF THE DEVICE HISTORY RECORD, WHICH SHOWED THAT EACH MFG AND INSPECTION OPERATION WAS PERFORMED AND INDICATED COMPLETE IN ACCORDANCE WITH SJM SPECIFICATIONS AND PROCEDURES. BASED ON THE INFO RECEIVED, THE CAUSE OF THE REPORTED ASYSTOLE COULD NOT BE CONCLUSIVELY DETERMINED.

Description of Event or Problem · 1

PREVIOUS TRANSSEPTAL PUNCTURE. THE PHYSICIAN WAS PREPARING TO PERFORM A SECOND TRANSSEPTAL PUNCTURE USING A FAST CATH SWARTZ INTRODUCER WITH A NON-SJM TRANSSEPTAL NEEDLE WHEN HE NOTED THE PT WAS IN ASYSTOLE. CHEST COMPRESSIONS WERE INITIATED AND UNSUCCESSFUL ATTEMPTS WERE MADE TO PACE THE PT FROM THE INQUIRY CATHETER LOCATED IN THE OS. THE INQUIRY CATHETER WAS WITHDRAWN FROM THE CS AND PLACED IN THE RIGHT VENTRICLE (RV) TO SUCCESSFULLY PACE THE PT. APPROX 45 SECONDS LATER A RECORDABLE HEART RATE RETURNED AND THE PT CONVERTED TO SINUS RHYTHM TWO MINS AFTER EPINEPHRINE AND ATROPINE WERE ADMINISTERED. A RIGHT BUNDLE BRANCH BLOCK WAS NOTED AND AN ECHOCARDIOGRAM VIA NON-SJM ICE CATHETER REVEALED A VENTRICULAR WALL ABNORMALITY, WHICH COULD NOT BE FOUND POST-PROCEDURE. A CORONARY ANGIOGRAM WAS PERFORMED, REVEALING NO ABNORMALITIES; THEREFORE, NO INTERVENTION WAS ADMINISTERED. AN INQUIRY QUADRIPOLAR CATHETER WAS INSERTED TO ASSIST WITH AN EP STUDY TO ASSESS THE PT'S CONDUCTION SYSTEM, WHICH REVEALED NO ABNORMALITIES. THE PROCEDURE WAS ABORTED AND THE PT WAS TRANSFERRED TO CRITICAL CARE. NO ABLATION WAS PERFORMED OR GEOMETRY CREATED PRIOR TO THE PERIOD OF ASYSTOLE. THE PHYSICIAN DID NOT ALLEGE ANY PERFORMANCE ISSUES WITH A SJM DEVICE AND THE CAUSE FOR THE ASYSTOLE WAS NOT IDENTIFIED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
247867 THERAPY COOL PATH CATHETER, 1304-CP-7-25-L-AB (USA) CARDIAC ABLATION PERCUTANEOUS CATHETER OAD ST. JUDE MEDICAL, INC. (AF-IRVINE) 84309 3922428

Patients

Seq Age Sex Outcome Treatment
1 62 YR Required Intervention INQUIRY STEERABLE CATHETER ((B)(4))| AGILIS NXT INTRODUCER ((B)(4))| FAST CATH SWARTZ INTRODUCER ((B)(4))| VELOCITY MAPPING SYSTEM| BRK TRANSSEPTAL NEEDLE ((B)(4))| CORDIS SHORT INTRODUCER