FDA Adverse Event
Injury
Summary report: N
MEDICHOICE
MDR report key: 3131066
·
Received May 23, 2013
Report
- Report Number
- 3003753847-2013-00009
- Event Type
- Injury
- Date Received
- May 23, 2013
- Report Date
- January 4, 2013
- Manufacturer
- DALIAN GOODWOOD MEDICAL CARE LTD.
- Product Code
- KXF
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Distributor report
- Reporter Occupation
- NURSE
Narratives
Description of Event or Problem · 1
THE MEDICAL DEVICE ASSOCIATED WITH THIS REPORT IS A NON-STERILE, RAYON-FIBER TIPPED APPLICATOR (OB/GYN) CONSISTING OF A PLASTIC STICK AND THE RAYON-FIBER BUD. IT WAS COMMUNICATED THAT THE FIBER TIP KEEPS COMING OFF IN THE PATIENT WHILE DOCTORS ARE SWABBING INSIDE THE PATIENT'S VAGINA. THE MANUFACTURER STATED THAT IN (B)(6) 2011 THEY REDUCED THE CONCENTRATION OF GLUE WHICH WAS USED TO SECURE THE RAYON TIP TO THE PLASTIC SHAFT. THE LOW CONCENTRATION OF GLUE USED TO SECURE THE RAYON TIP TO THE PLASTIC SHAFT WAS DETERMINED TO BE THE MOST PROBABLE ROOT CAUSE OF THE FIBER TIP COMING OFF.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 230414 | MEDICHOICE | RAYON TIPPED OB/GYN APPLICATOR | KXF | DALIAN GOODWOOD MEDICAL CARE LTD. | 1209DG13A |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |