- Report Number
- 0001056128-2013-00075
- Event Type
- Malfunction
- Date Received
- May 15, 2013
- Date of Event
- March 29, 2013
- Report Date
- April 23, 2013
- Manufacturer
- STRYKER SUSTAINABILITY SOLUTIONS LAKELAND
- Product Code
- NLQ
- PMA / PMN Number
- K043315
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- NURSE
Narratives
THE COMPLAINT DEVICE WAS RETURNED TO STRYKER SUSTAINABILITY SOLUTIONS (SSS) FOR AN EVALUATION. A VISUAL EXAMINATION OF THE RETURNED DEVICE REVEALED THAT THE DISTAL TIP OF THE SCALPEL BLADE WAS BROKEN OFF. MICROSCOPIC INSPECTION OF THE SCALPEL BLADE REVEALED A GOUGE ON THE SCALPEL BLADE. THERE WAS ALSO AN INDENTION IN THE TEFLON PAD. THE OBSERVED PAD INDENTION IS TYPICALLY CAUSED BY CLOSING THE JAW WITHOUT TISSUE BETWEEN THE ACTIVATED BLADE AND PAD, WHICH SUGGESTS THE JAW WAS INITIALLY INTACT DURING CLINICAL USE. BASED ON THE DAMAGE OBSERVED, THE MOST LIKELY CAUSE FOR THE REPORT WAS DETERMINED TO BE AN IMPACT OF THE JAW WITH A HARD OBJECT SUCH AS A STAPLE OR SURGICAL CLIP DURING CLINICAL USE. STRYKER SUSTAINABILITY SOLUTIONS' INSTRUCTIONS FOR USE STATE: "AVOID CONTACT WITH ANY AND ALL METAL OR PLASTIC INSTRUMENTS OR OBJECTS DURING INSTRUMENT ACTIVATION. CONTACT WITH STAPLES, CLIPS, OR OTHER INSTRUMENTS DURING INSTRUMENT ACTIVATION MAY RESULT IN PREMATURE BLADE FAILURE, RESULTING IN GENERATOR SOLID TONE OR INSTRUMENT ERROR." A REVIEW OF THE LOT CONTROL SHEET FOR THE REPORTED DEVICE SERIAL NUMBER INDICATED THE DEVICE PASSED ALL INSPECTIONS PRIOR TO RELEASE FROM SSS. THIS REPORT IS BEING FILED AS A MALFUNCTION DUE TO SSS BEING IN A 2 YEAR REPORTING CYCLE DUE TO MDR REPORT 1056128-2011-00021 WHERE THE TIP OF THE DEVICE REMAINED IN THE PATIENT EVEN THOUGH THERE WAS NO PATIENT INJURY IN THIS EVENT. THE REPORTED EVENT IS NOT OCCURRING MORE FREQUENTLY OR WITH GREATER SEVERITY THAN IS USUAL FOR THE DEVICE.
IT WAS REPORTED, "AFTER USING THE HARMONIC ACE SHEARS THE SURGICAL TECHNOLOGIST REALIZED ONE OF THE JAWS HAD BROKE OFF OF THE INSTRUMENT. THE BROKEN PIECE OF THE JAW AS WELL AS THE INSTRUMENT WERE PRESENT IN THEIR ENTIRETY." NO PATIENT INJURY WAS REPORTED BY THE USER FACILITY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 214421 | NA | NLQ | NLQ | STRYKER SUSTAINABILITY SOLUTIONS LAKELAND | ACE36E | 2377478 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 56 YR |