PINNACLE MTL INS NEUT40IDX56OD
Report
- Report Number
- 1818910-2013-16857
- Event Type
- Injury
- Date Received
- May 9, 2013
- Date of Event
- April 11, 2013
- Report Date
- April 11, 2013
- Manufacturer
- DEPUY ORTHOPAEDICS INC US
- Product Code
- KWA
- PMA / PMN Number
- PK062426
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- PATIENT
Narratives
THE DEVICES ASSOCIATED WITH THIS REPORT WERE NOT RETURNED. A SEARCH OF THE COMPLAINT DATABASE AND/OR DHR REVIEW WAS NOT POSSIBLE AS THE PRODUCT AND LOT CODES REQUIRED WERE NOT PROVIDED. THE INVESTIGATION COULD NOT DRAW ANY CONCLUSIONS REGARDING THE REPORTED EVENT WITH THE INFORMATION AVAILABLE. BASED ON THE INABILITY TO DETERMINE A ROOT CAUSE, THE NEED FOR CORRECTIVE ACTION WAS NOT INDICATED. DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD THE PRODUCT AND/OR ADDITIONAL INFORMATION BE RECEIVED, THE INVESTIGATION WILL BE RE-OPENED.
IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. THIS COMPLAINT IS STILL UNDER INVESTIGATION. DEPUY WILL NOTIFY THE FDA OF THE RESULTS OF THE INVESTIGATION ONCE IT HAS BEEN COMPLETED.
PATIENT SEEKING LEGAL ACTION.
NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. BASED ON PREVIOUS INVESTIGATIONS THIS COMPLICATION OF JOINT REPLACEMENT IS UNLIKELY TO HAVE BEEN THE RESULT OF A DEVICE FAILING TO MEET REQUIRED SPECIFICATIONS. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS, POST MARKET SURVEILLANCE, OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. CORRECTIVE ACTION WAS NOT INDICATED.
PRODUCT COMPLAINT # (B)(4).
(B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
LEGAL CLAIM RECEIVED. IT IS ALLEGED THAT THE PATIENT SUFFERS FROM PAIN AND ELEVATED LEVELS OF COBALT CHROMIUM.
IN ADDITION TO WHAT WAS PREVIOUSLY ALLEGED, LITIGATION ALLEGES THAT THE CORROSION AND FRICTION WEAR CAUSED TOXIC COBALT-CHROMIUM METAL DEBRIS TO BE RELEASED INTO THE PLAINTIFF'S TISSUE SURROUNDING THE IMPLANT. DOI: (B)(6) 2010 - DOR: (B)(6) 2015 (LEFT HIP)
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 203284 | PINNACLE MTL INS NEUT40IDX56OD | METAL LINER | KWA | DEPUY ORTHOPAEDICS INC US | 2763085 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 63 YR | Other | 12/14 ARTICUL 40MM M SPEC+8.5| APEX HOLE ELIM POSITIVE STOP| PINNACLE 100 ACET CUP 56MM| SUMMIT POR TAPER SZ7 STD OFF |