FDA Adverse Event Injury Summary report: N

UNK -- IOL

MDR report key: 3093658 · Received May 1, 2013

Report

Report Number
1119421-2013-00467
Event Type
Injury
Date Received
May 1, 2013
Manufacturer
ALCON RESEARCH. LTD . HUNTINGTON
Product Code
HQL
PMA / PMN Number
UNK
Removal / Correction Number
NA
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

EVALUATION SUMMARY: THE PRODUCT WAS NOT RETURNED FOR ANALYSIS. THE PRODUCT HISTORY RECORDS COULD NOT BE REVIEWED BECAUSE THE REPORTING FACILITY DID NOT PROVIDE A LOT NUMBER OR ANY IDENTIFICATION TRACEABLE TO THE MANUFACTURING DOCUMENTATION. THE PRODUCT INVESTIGATION COULD NOT IDENTIFY A ROOT CAUSE. NOT ENOUGH INFORMATION WAS PROVIDED FORM THE ACCOUNT FOR FURTHER INVESTIGATION. HONG Y, SUN YX, HONG C, ZHOU JC, HAO Y. PIGMENT DISPERSION GLAUCOMA INDUCED BY THE CHAFING EFFECT OF INTRAOCULAR LENS HAPTICS IN ASIAN EYES. CURRENT EYE RESEARCH, 2013, 38(3): 358-62. (B)(4).

Description of Event or Problem · 1

THE AUTHORS OF A JOURNAL ARTICLE REPORT THE FINDINGS OF PIGMENT DISPERSION GLAUCOMA (PDG) INDUCED BY THE CHAFING EFFECT OF SINGLE PIECE ACRYLIC (SPA) INTRAOCULAR LENSES (IOLS) IN ASIAN EYES. THE AUTHORS REPORTED THE RESULTS OF A RETROSPECTIVE STUDY OF PTS REFERRED TO THEIR HOSPITAL BETWEEN APRIL 2005 TO JUNE 2011. THE PURPOSE OF THIS STUDY WAS TO EXAMINE THE POSSIBLE MECHANISMS OF AND TREATMENT FOR PDG CAUSED BY SPA IOL CILIARY SULCUS FIXATION IN ASIAN EYES. A TOTAL OF SIX EYES FROM FIVE PTS WERE STUDIED. A SLIT LAMP EXAMINATION SHOWED THAT THE IOLS WERE COMPLETELY OR PARTIALLY OUTSIDE THE CAPSULAR BAG. POSTERIOR CAPSULE RUPTURE AND BROKEN LENS ZONULES WERE OBSERVED IN THREE EYES AND TWO EYES, RESPECTIVELY. PIGMENTATION DEPOSITS ON THE OPTICAL PART OF THE IOL WERE NOTED IN ALL PTS. A TYPICAL SLIT-LAMP PHOTOGRAPH OF A PT'S EYE SHOWED THE UPPER IOL HAPTIC WAS IN THE CILIARY SULCUS, AND IRIS TRANSILLUMINATION DEFECTS WAS NOTED IN THE UPPER HAPTIC REGION. OPTICAL COHERENCE TOMOGRAPHY (OCT) SHOWED THAT THE IOL WAS ANTERIOR TO THE CAPSULAR BAG, AN THE HAPTIC WAS IN CONTACT WITH THE REAR IRIS SURFACE, WHICH MAY HAVE CAUSED IRIS CHAFING. THE IOLS WERE REPOSITIONED IN THREE EYES BECAUSE THE CAPSULAR BAG COULD BE REOPENED IN THESE EYES, AND THE IOL WAS REPOSITIONED IN THE BAG. A COMBINED TRABECULECTOMY WAS PERFORMED IN TWO EYES WITH PROGRESSIVE VISUAL FIELD DEFECTS. THE CAPSULAR BAG OF THE OTHER THREE EYES WAS DIFFICULT TO REOPEN; THEREFORE, AN IOL EXCHANGE WAS PERFORMED USING A THREE PIECE IOL WITH CILIARY SULCUS FIXATION. ALL THE PTS HAD SIMULTANEOUS ANTERIOR VITRECTOMY. THE IOP WAS CONTROLLED WITHOUT VISUAL FIELD DEFECT PROGRESSION. IN THE REPORTED STUDY, THE AUTHORS FOUND THAT ALL PTS ENROLLED HAD SECONDARY GLAUCOMA WITHIN A MONTH AFTER CATARACT SURGERY. THE AUTHORS HYPOTHESIZE THAT THIS COULD BE DUE TO THE HIGHER PIGMENTATION IN ASIAN PTS COMPARED TO CAUCASIAN PTS. WHEN CHAFING OCCURS, THERE ARE MORE EXFOLIATED IRIS PIGMENTS, THE SYMPTOMS ARE MORE SEVERE, AND THE TRABECULAR MESHWORK IS MORE EASILY OBSTRUCTED. OTHER POSSIBLE REASON MAY INCLUDE THICKER IRIS AND SHORTER AXIAL LENGTH OF ASIAN EYES WHICH MAKES THE ASIAN EYES MORE PRONE TO HAVE CHAFING OF IRIS PIGMENT EPITHELIALIUM WITH SPL IOL HAPTICS. THESE ANATOMICAL DIFFERENCE MAY INDUCE MORE SEVERE PDG THAT REQUIRES SURGICAL INTERVENTION. THIS REPORT IS FOR THE FIRST PT WHO WAS BILATERALLY IMPLANTED. FOR THIS PT, AN IOL REPOSITIONING PROCEDURE WAS PERFORMED WITH A TRABECULECTOMY. THERE ARE SIX MEDICAL DEVICE REPORTS ASSOCIATED WITH THIS EVENT. THIS REPORT IS FOR THE FIRST PT, LEFT EYE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
188943 UNK -- IOL INTRAOCULAR LENS HQL ALCON RESEARCH. LTD . HUNTINGTON UNK UNK

Patients

Seq Age Sex Outcome Treatment
1 61 YR Required Intervention