1.8MM VA LOCKING BUTTRESS PIN W/T8 STARDRIVE RECESS/18MM
Report
- Report Number
- 2520274-2013-02275
- Event Type
- Injury
- Date Received
- May 2, 2013
- Date of Event
- April 3, 2013
- Report Date
- April 3, 2013
- Manufacturer
- SYNTHES USA
- Product Code
- HRS
- PMA / PMN Number
- K102694
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KY, US
- Reporter Occupation
- HEALTH PROFESSIONAL
Narratives
THIS DEVICE USED FOR TREATMENT AND NOT DIAGNOSIS. THESE PARTS WHEN CONSIDERED AS A WHOLE WOULD CONSTITUTE A VARIABLE ANGLE LOCKING BUTTRESS PIN. SPECIFICALLY, A LOCKING HEAD WITH STARDRIVE RECESS AND PLAIN SHAFT WITH THREADS NEAR THE HEAD IDENTIFY THIS AS A BUTTRESS PIN. THE CALCULATED LENGTH OF 18.61MM WOULD MAKE THIS A 02.210.088. PLEASE NOTE THAT THERE IS NO COMBINATION OF SHAFTS AND HEADS PROVIDED THAT WOULD YIELD A 02.210.086 SINCE THE SHORTEST SHAFT, WITHOUT A HEAD, IS 16.09MM THE TOTAL LENGTH OF A 02.210.086 IS 16MM. THE DRIVE IS IN FAIR CONDITION WITH LIGHT TO MODERATE DAMAGE. THE TOP OF THE HEAD IS ALSO DAMAGED WITH SOME LIGHT MATERIAL DISPLACEMENT. THE HEAD THREADS HAVE BEEN LIGHTLY DAMAGED NEAR THE TRANSITION WITH THE MAJOR BEING BENT SLIGHTLY UPWARDS TOWARDS THE TOP OF THE HEAD. THE BREAK IS AT THE NECK AND APPEARS TO BE CLEAN WITH NO INVOLVEMENT OF THE DRIVE. THE SHAFT THREADS HAVE BEEN COMPRESSED AT THE MAJOR DIAMETER INTO A T. THERE ARE SMALL INDENTATIONS, CONSISTENT WITH AN EXTRACTION. THE THREADLESS PORTION OF THE SHAFT IS IN GOOD CONDITION. THE TIP RADIUS HAS SMALL MARKS THAT APPEARS TO BE A MINOR ABRASION. THE DIMENSIONS THAT COULD BE MEASURED ARE IN TOLERANCE. DUE TO THE TYPE AND EXTENT OF DAMAGE INCURRED, AND ALSO BECAUSE NO LOT NUMBER WAS PROVIDED, A FINITE EVALUATION WAS NOT POSSIBLE. CORRECT PART NUMBER FOUND IN MANUFACTURING EVALUATION.
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. WITHOUT A LOT NUMBER, THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. SUBJECT DEVICE HAS BEEN RECEIVED AND IS CURRENTLY IN THE EVALUATION PROCESS. INVESTIGATION IS ON GOING; NO CONCLUSION COULD BE DRAWN. PLACEHOLDER.
PATIENT COMPLAINED OF PAIN AFTER FALLING FROM BED. DURING A DISTAL RADIUS REVISION SURGERY ON (B)(6) 2013, IT WAS DISCOVERED THAT TWO VARIABLE ANGLE LOCKING BUTTRESS PINS WERE SHEARED OR BROKEN AT THE HEAD OF THE PLATE. THIS OCCURRED AT THE JUNCTION WHERE THE SHAFT MEETS THE HEAD OF THE PIN. THE HEADS OF THE PINS REMAINED LOCKED IN THE PLATE. THE PINS WERE EXPLANTED. NO NEW HARDWARE WAS IMPLANTED. NO ADDITIONAL INFORMATION IS AVAILABLE. THIS IS REPORT 3 OF 3 FOR COMPLAINT (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 192983 | 1.8MM VA LOCKING BUTTRESS PIN W/T8 STARDRIVE RECESS/18MM | HRS | SYNTHES USA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 56 YR | Required Intervention |