FDA Adverse Event Injury Summary report: N

CARPENTIER-MCCARTHY-ADAMS IMR ETLOGIX MITRAL ANNULOPLASTY RING

MDR report key: 3090275 · Received May 2, 2013

Report

Report Number
2015691-2013-19968
Event Type
Injury
Date Received
May 2, 2013
Date of Event
April 2, 2013
Report Date
April 2, 2013
Manufacturer
EDWARDS LIFESCIENCES
Product Code
KRH
PMA / PMN Number
K083623
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

METHOD: DEVICE NOT RETURNED. THE ARTICLE CONCLUSION READS: IN SELECTED PATIENTS WITH CHRONIC ISCHEMIC LV DYSFUNCTION, MITRAL ANNULOPLASTY WITH THE IMR ETLOGIX RING, COMBINED WITH COMPLETE MYOCARDIAL REVASCULARIZATION, RESTORED THE MITRAL APPARATUS GEOMETRY AND COMPETENCE. AN EMAIL HAS BEEN SENT TO THE AUTHOR REQUESTING ADDITIONAL INFORMATION AND CLARIFICATION OF INFORMATION WITHIN THE ARTICLE. NO RESPONSE HAS BEEN RECEIVED TO DATE. NO PATIENT IDENTIFIER INFORMATION WAS PROVIDED IN THE ARTICLE. NO DEVICE IS INDICATED AS AVAILABLE FOR RETURN. AFTER REVIEW OF THE ARTICLE, IT WAS DETERMINED THAT ONE PATIENT REPORTEDLY HAD HIS RING EXPLANTED AND UNDERWENT SUCCESSFUL MITRAL VALVE REPLACEMENT DUE TO (B)(6) AT 54 DAYS AFTER HOSPITAL DISCHARGE. SOURCE OF THE INFECTION REMAINS UNKNOWN. ALTHOUGH THIS MOST LIKELY WAS NOT DUE TO A MALFUNCTION OR DEFICIENCY OF THE DEVICE, IT HAS NOT BEEN DISASSOCIATED BY THE HEALTH CARE PROVIDER.

Description of Event or Problem · 1

INFORMATION WAS RECEIVED FROM AN ARTICLE PUBLISHED IN THE JOURNAL OF HEART VALVE DISEASE, 'MITRAL ANNULOPLASTY WITH IMR ETLOGIX RING FOR ISCHEMIC MITRAL REGURGITATION AND LEFT VENTRICULAR DYSFUNCTION;' GIUSEPPE GATTI, BRUNO PINAMONTI, LUCA DELL-ANGELA, FRANCESCO ANTONINI-CANTERIN, BERNARDO BENUSSI, GIANFRANCO SINAGRA, ANIELLO PAPPALARDO. ABSTRACT: CHRONIC ISCHEMIC MITRAL REGURGITATION (IMR) IS ASSOCIATED WITH ASYMMETRIC MITRAL LEAFLET TETHERING AND ANNULAR DILATION. THE CARPENTIER-MCCARTHY-ADAMS IMR ETLOGIXR ANNULOPLASTY RING IS DESIGNED SPECIFICALLY TO TREAT THESE ASYMMETRIC PATHOLOGICAL CHANGES. IN THE PRESENT STUDY, THE RESULTS OF MITRAL ANNULOPLASTY WITH THIS RING IN A SELECTED SUBSET OF PATIENTS WITH SIGNIFICANT IMR AND LEFT VENTRICULAR (LV) DYSFUNCTION WERE ANALYZED. RESULTS: ALL PATIENTS UNDERWENT COMPLETE MYOCARDIAL REVASCULARIZATION. ONE (3%) IN-HOSPITAL (NON-CARDIAC) DEATH OCCURRED. DURING A MEAN FOLLOW UP OF 3.4 +/-1.5 YEARS (RANGE: 0.2 TO 5.9 YEARS), ONE EARLY MITRAL REPLACEMENT WAS REQUIRED (DUE TO ENDOCARDITIS), AND THERE WERE TWO CARDIAC DEATHS AND THREE NON-CARDIAC DEATHS. THE FOUR-YEAR ACTUARIAL SURVIVAL AND FREEDOM FROM HEART FAILURE HOSPITAL READMISSION WERE 82% AND 75%, RESPECTIVELY. HEART FAILURE SYMPTOMS WERE IMPROVED (P = 0.001), AND IMR WAS WELL CONTROLLED WITHIN GRADE 1+ (P <0.0001) FOR THE 24 REMAINING PATIENTS. THE MAD, TA AND TH WERE EACH DECREASED IN ALL THREE ECHOCARDIOGRAPHIC VIEWS (P =0.0006). THE MAD REDUCTION WAS GREATER IN THE LONG-AXIS VIEW THAN IN THE FOUR-CHAMBER (56% VERSUS 49%, P = 0.002) AND TWO-CHAMBER (56% VERSUS 43%, P = 0.0003) VIEWS. CONCLUSION: IN SELECTED PATIENTS WITH CHRONIC ISCHEMIC LV DYSFUNCTION, MITRAL ANNULOPLASTY WITH THE IMR ETLOGIX RING, COMBINED WITH COMPLETE MYOCARDIAL REVASCULARIZATION, RESTORED THE MITRAL APPARATUS GEOMETRY AND COMPETENCE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
191454 CARPENTIER-MCCARTHY-ADAMS IMR ETLOGIX MITRAL ANNULOPLASTY RING RING, ANNULOPLASTY KRH EDWARDS LIFESCIENCES 4100

Patients

Seq Age Sex Outcome Treatment
1 Hospitalization| R