SUPERFLEX
Report
- Report Number
- 9611165-2013-00028
- Event Type
- Injury
- Date Received
- April 19, 2013
- Report Date
- February 20, 2013
- Manufacturer
- RAYNER INTRAOCULAR LENSES LIMITED
- Product Code
- HQL
- PMA / PMN Number
- P060011
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- LE
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4) HAS BEEN ALLOCATED TO THIS CASE BY RAYNER INTRAOCULAR LENSES LIMITED. THE LITERATURE STATES "SUBSEQUENTLY SHE HAD PHACOEMULSIFICATION WITH HYDROPHILIC ACRYLIC INTRAOCULAR LENS (SUPERFLEX, RAYNER INTRAOCULAR LENS (B)(4); 6.25 MM OPTIC AND 12.5 MM OVERALL LENGTH) IMPLANTATION IN THE BAG WITH ZONULAR DEHISCENCE. VISUAL ACUITY WAS 6/9 IN THE LEFT EYE WITH MILD DECENTRATION. THE PT WAS REFERRED FOR SCLERAL FIXATION OF THE LENS. BECAUSE OF SCLERAL THINNING AND HISTORY OF RETINAL DETACHMENT, WE PROCEEDED WITH IRIS SUTURE FIXATION... TEN HOURS POST-OPERATIVELY, THE PT HAD FINGER COUNTING AT 10 CM WITH FIBRINOUS PANUVEITIS AND DENSE ECHOSE ON B-SCAN. THE POSSIBILITY OF ENDOPHTHALMITIS WAS DISCUSSED WITH THE PT WHO DECLINED IMMEDIATE AQUEOUS PARACENTESIS FOR CULTURE PURPOSES. SHE WAS THEREFORE FOLLOWED UP SEVERAL TIMES DAILY INITIALLY... VISUAL ACUITY IMPROVED TO 6/21 ONE WEEK POSTOPERATIVELY WITH MINIMAL IRITIS... SHE REPORTED A GRADUAL RECOVERY OF PREOPERATIVE VISION 5 WEEKS AFTER SURGERY". DUE TO SCLERAL THINNING AND A HISTORY OF RETINAL DETACHMENT, THE SURGEONS PROCEEDED WITH IRIS SUTURE FIXATION OF THE LENS. THE INFORMATION AVAILABLE WITHIN THE PUBLISHED PAPER INDICATES THAT PT CONDITIONS WERE A CONTRIBUTING FACTOR IN THE DEVELOPMENT OF POST-OPERATIVE FULMINANT PANUVEITIS.
RAYNER INTRAOCULAR LENSES LIMITED IDENTIFIED A PUBLISHED PAPER ENTITLED 'FULMINANT PANUVEITIS FOLLOWING IRIS SUTURE FIXATION OF POSTERIOR CHAMBER INTRAOCULAR LENS' DURING A ROUTINE LITERATURE SEARCH. FURTHER REVIEW OF THE PUBLISHED ARTICLE ESTABLISHED THAT A RAYNER INTRAOCULAR LENSES LIMITED MANUFACTURED INTRAOCULAR LENS (SUPERFLEX, MODEL NUMBER NOT STATED) WAS INVOLVED IN THIS INCIDENT. THE LITERATURE STATES "WE PRESENT A CASE OF FULMINANT PANUVEITIS FOLLOWING IRIS SUTURE FIXATION OF A POSTERIOR CHAMBER INTRAOCULAR LENS. WE HYPOTHESIZE THAT THE ZONULAR DEHISCENCE ALLOWED THE INFLAMMATORY CELLS IN THE ANTERIOR COMPARTMENT TO GAIN ACCESS TO THE POSTERIOR SEGMENT MIMICKING ENDOPHTHALMITIS OR TOXIC ANTERIOR SEGMENT SYNDROME".
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 169881 | SUPERFLEX | HQL - INTRAOCULAR LENS | HQL | RAYNER INTRAOCULAR LENSES LIMITED | UNK | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 46 YR | Required Intervention |