FDA Adverse Event
Malfunction
Summary report: N
HOLMES
MDR report key: 3072313
·
Received April 5, 2013
Report
- Report Number
- 3003862163-2013-00053
- Event Type
- Malfunction
- Date Received
- April 5, 2013
- Report Date
- April 4, 2013
- Manufacturer
- JARDEN CONSUMER SOLUTIONS, DBA, SUNBEAM PRODUCTS
- Product Code
- KFZ
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- UNKNOWN
Narratives
Additional Manufacturer Narrative · 1
ABUSE BY THE CONSUMER FROM FAILURE TO TAKE PREVENTIVE ACTION TO PROPERLY CLEAN THE HUMIDIFIER CAUSED THIS FAILURE. SUMMARY: THE HEATING ELEMENT MELTED AT THE BOTTOM OF THE UNIT. THERE APPEARS TO BE A LAYER OF HEAVY MINERAL BUILD-UP ON THE HEATING ELEMENT AND THE HEATING CHAMBER, WHICH INDICATES THE CONSUMER DID NOT PROPERLY CLEAN THE UNIT, WHICH IS AN ABUSE OF THE PRODUCT. MOISTURE ENTERED THE UNIT AND PROVIDED AN ELECTRICAL PATH THAT BY-PASSED THE THERMOSTAT AND TCO NOT ALLOWING THE HEATER TO SHUT DOWN.
Description of Event or Problem · 1
CONSUMER ALLEGES HIS HUMIDIFIER STARTED TO MAKE NOISE AND EMIT SMOKE. NO INJURIES OR PROPERLY DAMAGES WERE REPORTED WITH THIS INCIDENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 140308 | HOLMES | HUMIDIFIER | KFZ | JARDEN CONSUMER SOLUTIONS, DBA, SUNBEAM PRODUCTS | HM5250 | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |