HOLDING SLEEVE-STANDARD FOR MATRIX
Report
- Report Number
- 1719045-2013-10760
- Event Type
- Malfunction
- Date Received
- April 22, 2013
- Date of Event
- December 17, 2011
- Report Date
- December 17, 2011
- Manufacturer
- SYNTHES MONUMENT
- Product Code
- LXH
- PMA / PMN Number
- EXEMPT
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- VA
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. ORIGINAL AWARENESS DATE IS (B)(6) 2011.
ADDITIONAL NARRATIVE: SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR. A REVIEW OF THE DEVICE HISTORY RECORDS WAS PERFORMED AND NO COMPLAINT RELATED ISSUES WERE FOUND. THE PRODUCT DEVELOPMENT EVALUATION REVEALED THAT THE FIRST TWO THREADS ON THE DISTAL END ARE PARTIALLY STRIPPED AND THE REMAINING THREADS HAVE DENTS AND BURRS. THE TIP CANNOT BE INSERTED INTO A SCREW DUE TO THE DAMAGE. THE TECHNIQUE GUIDE ILLUSTRATES HOW TO PROPERLY LOAD AND TIGHTEN THE HOLDING SLEEVE INTO THE RECESS OF THE SCREW AND CAUTIONS NOT TO GRASP THE GREEN KNOB DURING SCREW INSERTION AS THIS WILL CAUSE THE HOLDING SLEEVE TO DISENGAGE FROM THE SCREW. THE DAMAGE IS CONSISTENT WITH THAT NOTED IN PREVIOUS COMPLAINTS AND THAT EVALUATION STATES THAT THE CONDITION OF THE THREADS INDICATES THAT THE ENGAGED HOLDING SLEEVE WAS PARTIALLY UNTHREADED FROM THE IMPLANT INTERFACE, AT WHICH POINT A CANTILEVER LOAD WAS APPLIED TO THE ASSEMBLY. THIS INCOMPLETE ENGAGEMENT ALLOWED THE CANTILEVER FORCE TO CONCENTRATE ON ONE SECTION OF THE THREADS, EXCEEDING THE DESIGN LIMITS. THE BREAKAGE IS DUE TO THIS CONDITION AND AN INTERNAL CORRECTIVE ACTION HAS BEEN OPENED TO ADDRESS THIS ISSUE. THE CONDITION APPEARS TO BE THE RESULT OF THE SLEEVE BECOMING LOOSE DURING SCREW INSERTION WHICH CONTRIBUTED TO THE BREAKAGE. THIS CONDITION IS BEING ADDRESSED AND IS VALID BASED ON THE NUMBER OF COMPLAINTS RECEIVED FOR THIS CONDITION.
SYNTHES IS SUBMITTING THIS REPORT AS A RESULT OF REMEDIATION ACTIVITIES RELATED TO FDA WARNING LETTER DATED FEBRUARY 2012. DEVICE(S) LISTED IN THIS REPORT IS (ARE) USED FOR TREATMENT, NOT DIAGNOSIS. ANY ADDITIONAL INFORMATION RECEIVED REGARDING THIS EVENT AFTER FILING THIS REPORT SHALL BE FILED ON A SUPPLEMENTAL MDR.(B)(4).
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE, A PEDICLE PROBE BENT, THE TIP OF A LONG HOLDING SLEEVE BROKE OFF, AND THE HEADS OF TWO SCREWS BROKE OFF WHILE USING TWO STANDARD HOLDING SLEEVES. ALL BROKEN PIECES WERE RETRIEVED. ALL ITEMS ARE AVAILABLE FOR RETURN. THIS IS REPORT 3 OF 4 FOR COMPLAINT (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 172781 | HOLDING SLEEVE-STANDARD FOR MATRIX | LXH | SYNTHES MONUMENT | 6558993 |