TALENT AAA
Report
- Report Number
- 2953200-2013-00752
- Event Type
- Injury
- Date Received
- April 22, 2013
- Date of Event
- February 3, 2012
- Report Date
- June 27, 2013
- Manufacturer
- MEDTRONIC CARDIOVASCULAR
- Product Code
- MIH
- PMA / PMN Number
- P070027
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS, US
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4).
(B)(4). METHODS: (FILMS); RESULTS: INHERENT RISK OF PROCEDURE (ENDOLEAK). CONCLUSION: (INSUFFICIENT INFORMATION, CAUSE OF EVENTS IS UNKNOWN); KNOWN INHERENT RISK OF PROCEDURE (ENDOLEAK).
A TALENT STENT GRAFT SYSTEM WAS IMPLANTED IN A PATIENT FOR THE ENDOVASCULAR TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM. THE ANEURYSM DIAMETER WAS 5.4 CM. ADDITIONAL ANEURYSM AND VESSEL MORPHOLOGY INFORMATION WAS NOT REPORTED. AT THE INDEX PROCEDURE THE PATIENT RECEIVED A TALENT (B)(4) BIFURCATED STENT GRAFT AND AN ANEURX (B)(4) LIMB. APPROXIMATELY THREE YEARS AFTER THE INDEX PROCEDURE, THE PATIENT PRESENTED WITH A PROXIMAL TYPE I ENDOLEAK. ENDURANT (B)(4) CUFFS WERE IMPLANTED, AND THE ENDOLEAK RESOLVED. APPROXIMATELY FOUR YEARS AFTER THE INDEX PROCEDURE, THE PATIENT PRESENTED WITH A TYPE III FABRIC ENDOLEAK. AN ENDURANT (B)(4) LIMB WAS IMPLANTED, AND THE ENDOLEAK RESOLVED. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE. REVIEW OF A SINGLE STILL ANGIO IMAGE SHOWED CONTRAST OUTSIDE OF THE STENTLESS AREA OF THE IPSILATERAL LIMB; POSSIBLY DUE TO A TYPE III FABRIC ENDOLEAK. AN IMAGE AFTER RELINING WITH A LIMB SHOWED RESOLUTION OF THE ENDOLEAK. THE CAUSE OF THE ENDOLEAK COULD NOT BE DETERMINED FROM THIS IMAGE.
A REVIEW OF CTA'S 4 YEARS POST-IMPLANT SHOW THAT THE ENDURANT CUFF(S) WERE POSITIONED JUST BELOW THE RENAL ARTERIES. THE TALENT BIFURCATE WAS 2-3CM BELOW THE RENALS; THE ORIGINAL PLACEMENT OF THE TALENT IS UNKNOWN. THE AAA WAS 8CM MAX DIAMETER. THE IPSILATERAL LIMB WAS PLACED WITHIN THE LEFT ILIAC. THE AORTIC BODY WAS ANGULATED 90DEG TO THE LIMBS (A-P). BELOW THE ANGULATION, A POSSIBLE TYPE III FABRIC ENDOLEAK IS SEEN NEAR THE STENTLESS AREA OF THE IPSILATERAL LIMB IN THE DISTAL AAA SAC. THERE IS A LARGE AREA OF CALCIFICATION NEAR THE ENDOLEAK IN THE DISTAL AAA. THE CAUSE COULD NOT BE DETERMINED. IT IS POSSIBLE THAT CALCIFICATION MAY HAVE ABRADED THE FABRIC AND CAUSED THE TYPE III ENDOLEAK.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 171846 | TALENT AAA | SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT | MIH | MEDTRONIC CARDIOVASCULAR | V00183523 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 00090 YR | Required Intervention |